CLI Language Reference

CLI Command List

Set Remote T1Drop PRM

Purpose: Sets the T1 Drop performance message type to either ANSI T1.403 one-second Performance Report Messages (PRMs) or AT&T 54016 Maintenance Messages over the 4 Kbps ESF Facility Data Link (FDL).

Security: Level 2 (operator)

Syntax: set remote <n> t1drop prm <ansiatt>

Field

n

ansi

att

Description

DS1 number, 1 to 32.

Set to ANSI T1.403 performance report messages.

Set to AT&T 54016 maintenance messages.

Example: set remote 9 t1drop prm att

Set Remote V35 ClockInv

Purpose: Sets the Access Bank II V.35 interface transmit and receive clock polarity. The clock signals for each direction can be normal or inverted.

The Access Bank II provides a V.35 port for connection to a V.35 router. You can connect one or more DS0s to the V.35 port, using a fractional interface. If the router does not have automatic rate sensing, it will have to be programmed for the proper data rate. Use the show remote command to display the current settings stored in the Access Navigator’s data base.

Security: Level 2 (operator)

Syntax: set remote <n> v35 clkinv <rxtxrxtxnone>

Field

Description

 

 

n

DS1 number, 1 to 32.

 

 

rx

Invert receive clock only.

 

 

tx

Invert transmit clock only.

 

 

rxtx

Invert both receive and transmit clock.

 

 

none

No clock inversion.

 

 

Example: set remote 9 v35 clkinv none

18-124

August 2003

Access Navigator - Release 1.8

Page 580
Image 580
Carrier Access Access Navigator user manual Set Remote T1Drop PRM, Set Remote V35 ClockInv