CLI Language Reference

CLI Command List

Reset Remote

CAUTION! THE RESET REMOTECOMMAND WILL DISRUPT T1 VOICE AND DATA SERVICES THROUGH THE REMOTE ACCESS BANK II FOR ABOUT 15 SECONDS.

Purpose: Resets a remote Access Bank II connected to the Access Navigator through a DS1. This command resets and restores the Access Bank controllers, T1 connection, all crossconnections, and all remote interfaces to the configuration settings stored in nonvolatile memory.

The reset operation takes about 15 seconds, during which all T1 voice and data services through the remote Access Bank II will be disrupted. Management communications with the remote terminal will also be disabled for about 15 seconds (30 seconds for a remote Access Bank II/SNMP).

Security: Level 2 (operator)

Syntax: reset remote <n>

Field

Description

 

 

n

DS1 number, 1 to 32, or a range of numbers such as 2-8.

 

 

Example: reset remote 9

Reset Standby

Purpose: Produces a soft reset of the standby Controller card. The entire process takes about 30 seconds. You can use the status equipment command to verify operational status of the standby Controller card.

Security: Level 2 (operator)

Syntax: reset standby

The reset standby command has the following effects:

￿Resets only the standby Controller card.

￿Does not disrupt service or active Controller operation.

￿Upon restart, the standby Controller receives the current database configuration settings and status data from the active Controller.