Provision Remote Access Bank II

Configure Remote RS-232 Interface (if used)

3. Set baud rate with the following command:

set remote <n> rs232 baud <setting> Example: set remote 11 rs232 baud 9600

Available baud settings are: 1200, 2400, 4800, 9600, 19200, 38400, 57600.

4.Set number of data bits and parity with the following command: set remote <n> rs232 data <e7o7n8>

Example:

set remote 11 rs232 data n8

5.Set number of stop bits with the following command: set remote <n> rs232 stop <12>

Example:

set remote 11 rs232 stop 1

Access Navigator - Release 1.8

August 2003

11-23

Page 271
Image 271
Carrier Access Access Navigator user manual Set baud rate with the following command