CLI Language Reference

CLI Command List

Syntax: set remote <n> rs232 baud <setting>

Field

n

setting

Description

DS1 number, 1 to 32

Baud rate selections are:

1200, 2400, 4800, 9600, 19200, 38400, 57600

Example: set remote 9 rs232 baud 57600

Set Remote RS232 Data

Purpose: Sets Access Bank II remote RS-232 interface data bits and parity.

Security: Level 2 (operator)

Syntax: set remote <n> rs232 data <e7o7n8>

Example: set remote 9 rs232 data n8

Field

n

e7

o7

n8

Description

DS1 number, 1 to 32

7 bit data, even parity

7 bit data, odd parity

8 bit data, no parity

Set Remote RS232 Stop

Purpose: Sets Access Bank II remote RS-232 interface stop bits.

Security: Level 2 (operator)

Syntax: set remote <n> rs232 stop <12>

Field

n

12

Description

DS1 number, 1 to 32.

Number of stop bits, 1 or 2.

Example: set remote 9 rs232 stop 1

Access Navigator - Release 1.8

August 2003

18-121

Page 577
Image 577