Provision GR-303 Service

Set System Switch Type

Set System Switch Type

NOTE: Access Navigator supports Lucent 5ESS, Nortel DMS, and generic Telcordia GR-303 switch types.

1. Show switch type with the following command:

show switch

2.If switch type is correct, skip remaining steps.

3.Set switch type with the following command:

set switch type <5essdmsgeneric>

Example:

set switch type 5ess

Set System Clock Source

NOTE: For GR-303 call support, the primary and secondary clock sources are usually set to two DS1s within the GR-303 Interface Group.

1.Show current clock settings with the following command: show clock

This command will produce a message similar to the following:

Primary Master Transmit Clock Source: DS1 25

Secondary Master Transmit Clock Source: DS1 29

2.If clock settings are correct, skip remaining steps.

3.Set clock primary (clock1) source with the following command: set clock1 <setting>

Example: set clock1 bits

There are three different settings, which are defined as follows:

Setting

Definition

bits

Select external or BITS source on Timing In connector

ds1 <n>

Select clock recovered from DS1 number n

internal

Select internal oscillator

4.Set clock secondary (clock2) source with one of the following commands: set clock2 <setting>

Example:

set clock2 ds1 5

Choose setting from list in previous step.

10-14

August 2003

Access Navigator - Release 1.8

Page 228
Image 228
Carrier Access Access Navigator user manual Set System Switch Type, Show switch