Provision GR-303 Service

Turn Up Service

Turn Up Service

1.Show current DS1 status with the following command: status ds1 <n>

Example: status ds1 13

2.Show current DS0 status with the following command: status ds0 <n:ch>

Example: status ds0 13:1-16

3.If drop DS1 and DS0 settings are correct, skip remaining steps.

4.Set DS1s and DS0s to in-service (up) status with the following commands:

set

ds1 <n> up

set

ds0 <n:ch> up

Example:

set ds1

13 up

Example:

set ds0

13:1-16 up

Test Circuits

NOTE: The Access Navigator supports the following T1.403 loop tests:

Responds to ESF bit patterned loop requests (when loopdetect is on)

Generates ESF bit patterned loop requests

Generates SF CSU inband loopcodes

NOTE: The Access Navigator provides line and payload loopback commands for troubleshooting line problems. See Diagnostics & Troubleshooting on page 15-1.

1.Follow standard practices to test subscriber drop DS1 circuits.

2.Follow standard practices to test DS0 connections.