CLI Language Reference

 

 

CLI Command List

 

 

 

 

 

 

 

Field

Description

 

 

 

 

p2e11

Send 211–1 pattern with a maximum of 10 consecutive zeros and

 

 

11 consecutive ones. (Minimum stress testing.)

 

 

 

 

p2e15

Send 215–1 pattern with a maximum of 14 consecutive zeros and

 

 

15 consecutive ones. (Provides maximum number of consecutive

 

 

zeros permissible in framed, non-B8ZS testing.)

 

 

 

 

p2e23

Send 223–1 pattern with a maximum of 22 consecutive zeros and

 

 

23 consecutive ones. (Maximum stress testing.)

 

 

 

 

qrss

Send QRSS pattern (a modified 220–1) with a maximum of 14

 

 

consecutive zeros and 20 consecutive ones. (Common stress test

 

 

for T1 data applications.)

 

 

 

Example: set ds1 9 payload p2e15 test

For p2e, qrss, and all-ones test patterns, the CLI will provide a progress message indicating the success (ok) or failure of the command followed by the bit error test results, as in the following sample.

Message: Waiting for pattern sync........ok.

 

 

Testing line...

BE:0

CRC:0

BPV/LCV:0

08:15:47

FBE:0

08:15:48

FBE:0

BE:0

CRC:0

BPV/LCV:0

08:15:49

FBE:0

BE:0

CRC:0

BPV/LCV:0

08:15:50

FBE:0

BE:0

CRC:0

BPV/LCV:0

08:15:51

FBE:0

BE:0

CRC:0

BPV/LCV:0

08:15:52

FBE:0

BE:0

CRC:0

BPV/LCV:0

08:15:54

FBE:0

BE:0

CRC:0

BPV/LCV:0

08:15:55

FBE:0

BE:0

CRC:0

BPV/LCV:0

08:15:56

FBE:0

BE:0

CRC:0

BPV/LCV:0

08:15:57

FBE:0

BE:0

CRC:0

BPV/LCV:0

FBE:

Totals

Error Rates

 

0

0.000000e+00

 

BE:

0

0.000000e+00

 

CRC:

0

0.000000e+00

 

LCV/BPV:

0

0.000000e+00

 

Signaling done.

The following error message will occur if an incorrect pattern is received:

Message: Waiting for pattern sync

no sync.

The following error message will occur if there is no loopback in effect:

Message: *-Unable to send code;

*- far-end is not in loopback.

Access Navigator - Release 1.8

August 2003

18-79

Page 535
Image 535
Carrier Access Access Navigator user manual Example set ds1 9 payload p2e15 test, P2e11