Provision Remote Access Bank II

Configure Remote T1 Drop Interface (if used)

3.Set remote T1 Drop framing to D4 (SF) or ESF with the following command: set remote <n> t1drop framing <d4esf>

Example:

set remote 11 t1drop framing d4

4.Set remote T1 Drop line buildout (lbo) to the required DSX-1 equalization or CSU attenuation with the following command:

set remote <n> t1drop lbo <setting>

Example:

set remote 11 t1drop lbo 1

The setting is a number from 1 to 9, and is defined as follows:

Setting Definition

1Set DSX-1 equalization for 0-133 ft.

2Set DSX-1 equalization for 133-266 ft.

3Set DSX-1 equalization for 266-399 ft.

4Set DSX-1 equalization for 399-533 ft.

5Set DSX-1 equalization for 533-666 ft.

6Set CSU attenuation for LBO of 0dB.

7Set CSU attenuation for LBO of -7.5dB.

8Set CSU attenuation for LBO of -15dB.

9Set CSU attenuation for LBO of -22.5dB.

5.Set remote T1 Drop line coding to AMI (alternate mark inversion) or B8ZS (binary 8 zero substitution with the following command:

set remote <n> t1drop linecode <amib8zs>

Example:

set remote 11 t1drop linecode b8zs

6.Set remote T1 Drop performance message (PRM) format to A&T 54016 or ANSI T1.402 with the following command:

set remote <n> t1drop prm <ansiatt>

Example:

set remote 11 t1drop prm att

Access Navigator - Release 1.8

August 2003

11-25

Page 273
Image 273
Carrier Access Access Navigator user manual Set remote n t1drop lbo setting, Set remote n t1drop linecode amib8zs