Alarm Clearing

DS1 Status LEDs

DS1 Status LEDs

Each Quad T1 Framer (QF) card has status indicators for four DS1s. The Access Navigator holds up to 8 QF cards, providing up to 32 DS1 circuits.

There are a total of 32 DS1 status LEDs on the front control panel, arranged in groups of 4, corresponding to the 4 DS1 interfaces of each installed QF card. An LED will be off if the associated DS1 interface is out of service or if there is no installed Quad Framer card for that interface. In order to display the many DS1 status states, each DS1 LED will show a specific color (red, yellow, green) and duty cycle (off, on, flash slow, flash fast).

Table 14-15. DS1 Status LEDs

LED State

Description

Troubleshooting

Off

Off-line

Individual DS1s can be taken out of

 

 

service by using the set ds1 down

 

 

command and put into service using the

 

 

set ds1 up command.

 

 

 

Green

Normal operation

Normal operation.

 

 

 

Green Flashing

Loopback test in progress

Tests may be initiated by local or remote

 

 

commands. Local self-tests are initiated

 

 

using the set ds1 line loopup and set ds1

 

 

payload loopup commands. Remote

 

 

tests use ANSI T1.403 in-band or FDL

 

 

commands.

 

 

 

Red

Loss of signal (LOS)

When the receiving unit detects a failure,

 

 

it will display a red alarm and send a T1

 

 

yellow alarm signal upstream toward the

 

 

cause of the problem (such as a cut

 

 

cable). Normally, the location of the fault

 

 

is somewhere between the units

 

 

displaying the red and yellow alarms.

 

 

 

Red Flashing Fast

Self-test failure

Retest DS1 using test ds1 command. If

 

 

test fails again, replace Quad Framer card

 

 

with known good card and test again.

 

 

 

Red Flashing Slow

Loss of frame (LOF) and/or

T1 problem exists, but the line is intact.

 

Alarm indication signal (AIS)

LOF indicates an upstream T1 transmit

 

 

problem exists, or that there is a framing

 

 

mismatch (ESF and D4) at the two ends.

 

 

An AIS (blue alarm) message is

 

 

transmitted downstream to indicate an

 

 

upstream problem exists.

 

 

 

14-20

August 2003

Access Navigator - Release 1.8

Page 340
Image 340
Carrier Access Access Navigator user manual 15. DS1 Status LEDs, Set ds1 up command