DATA BITS

 

 

 

 

 

COMMAND SET TYPE

 

D7

 

D6

 

 

 

 

 

(SEE DESCRIPTIONS FOR INDIVIDUAL COMMANDS)

 

 

 

 

 

 

 

 

 

0

 

 

0

 

 

START OR STOP COMMANDS

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

 

1

 

 

INITIAL SETUP COMMANDS

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

0

 

 

INITIAL SETUP COMMANDS

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

1

 

 

INPUT AND OUTPUT CONTROL COMMANDS

 

 

 

 

 

 

 

 

 

 

 

COMMAND BUFFER REGISTER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Description of Command

7

 

6

 

5

4

3

 

2

1

0

 

 

 

 

0

 

0

 

X

0

0

 

X

0

0

Changes to constant speed operation at the Base Speed rate. *

 

 

 

 

 

 

 

 

 

 

 

 

0

 

0

 

X

0

0

 

X

0

1

Changes to contant speed operation at the Max Speed rate. *

 

 

 

 

 

 

 

 

 

 

 

 

0

 

0

 

X

0

0

 

X

1

0

Ramps up or down to the Base Speed rate. *

 

 

 

 

 

 

 

 

 

 

 

 

0

 

0

 

X

0

0

 

X

1

1

Ramps up or down to the Max Speed rate. *

 

 

 

 

 

 

 

 

 

 

 

 

0

 

0

 

X

0

1

 

X

0

0

Changes immediately to the Base Speed rate and stops. *

 

 

 

 

 

 

 

 

 

 

 

 

0

 

0

 

X

0

1

 

X

0

1

Changes immediately to the Max Speed rate and stops. *

 

 

 

 

 

 

 

 

 

 

 

 

0

 

0

 

X

0

1

 

X

1

0

Ramps up or down to the Base Speed rate and stops. * **

 

 

 

 

 

 

 

 

 

 

 

 

0

 

0

 

X

0

1

 

X

1

1

Ramps up or down to the Max Speed rate and stops. * **

 

 

 

 

 

 

 

 

 

 

 

 

0

 

0

 

X

1

0

 

X

0

0

Starts at Base Speed operation or if already running changes to Base

 

 

 

 

 

 

 

 

 

 

 

Speed operation.

 

 

 

 

 

 

 

 

 

 

 

 

0

 

0

 

X

1

0

 

X

0

1

Starts at Max Speed operation or if already running changes to Max

 

 

 

 

 

 

 

 

 

 

 

Speed operation.

 

 

 

 

 

 

 

 

 

 

 

 

0

 

0

 

X

1

0

 

X

1

0

Starts at Base Speed (constant speed start) or if already running

 

 

 

 

 

 

 

 

 

 

 

ramps up or down to Base Speed operation.

 

 

 

 

 

 

 

 

 

 

 

 

0

 

0

 

X

1

0

 

X

1

1

Starts at Base speed and ramps to Max speed operation or if already

 

 

 

 

 

 

 

 

 

 

 

running ramps up or down to Max Speed operation.

 

 

 

 

 

 

 

 

 

 

 

 

0

 

0

 

X

1

1

 

X

0

0

Outputs a single pulse at Base Speed and Stops.

 

 

 

 

 

 

 

 

 

 

 

 

0

 

0

 

X

1

1

 

X

0

1

Outputs a single pulse at Max Speed and Stops.

 

 

 

 

 

 

 

 

 

 

 

 

0

 

0

 

X

1

1

 

X

1

0

If running, ramps up or down to Base speed and then stops. **

 

 

 

 

 

 

 

 

 

 

 

 

0

 

0

 

X

1

1

 

X

1

1

If running, ramps up or down to Max speed and then stops. **

 

 

 

 

 

 

 

 

 

 

 

 

START OR STOP COMMANDS

*If send during operations, otherwise no function

**For these commands, the pulse output cannot be stopped until the target pulse rate has been acheived or until a limit input has been reached.