Electrical Installation

Verify Operation

Verify Operation

NOTE: Verification requires a temporary loopback between the DS1 transmit and receive signals by cross-connecting newly installed DS1s at the patch panel.

1.If not currently logged into the Access Navigator, start an RS-232 management session (Start RS- 232 Management Session on page 7-6).

2.Display equipment status of Quad T1 Framer card with the following command:

status equipment

A message similar to the following will appear.

Equipment

Status

Version

---------

------

-------

Controller A

Active

01.70

Controller B

Standby

01.70

DS1 Card 1

Installed

1

DS1 Card 2

Installed

1

DS1 Card 3

Installed

1

DS1 Card 4

Installed

1

DS1 Card 5

Installed

1

DS1 Card 6

Installed

1

DS1 Card 7

Card not installed

 

DS1 Card 8

Card not installed

 

Requirement:

Equipment status shows DS1 card is installed.

NOTE: If status display shows that the card is not installed, check that the card is properly seated in the card connector.

3.Set DS1s on Quad T1 Framer card in service by entering the following command, where <n> is the DS1 number or range of DS1 numbers:

set ds1 <n> up

Example:

set ds1

9 up

Example:

set ds1

9-12 up

4. Loop back newly installed DS1 transmit outputs to DS1 receive inputs at patch panel.