Provision Remote Access Bank II

Provision DS0 Crossconnects

Provision DS0 Crossconnects

1.Show current crossconnect settings with the following command: show connect <n>

Example: show connect 11

The show command will display the current settings for the specified DS1. For example, the message for DS1 number 11 would look similar to the following:

Connections for DS1 #11 (CA DS1# 11):

From

To

Type Interface [--> Port]

--------- ----- --------------------

11:01 ..... GR303 11:02 ..... GR303 11:03 ..... GR303 11:04 ..... GR303 11:05 ..... GR303 11:06 ..... GR303 11:07 ..... GR303 11:08 ..... GR303 11:09 ..... GR303 11:10 ..... GR303 11:11 ..... GR303 11:12 ..... GR303 11:13 .....

11:14 .....

11:15 .....

11:16 .....

11:17 09:12 DATA AcmeInternet --> V.35 11:18 09:13 DATA AcmeInternet --> V.35 11:19 09:14 DATA AcmeInternet --> V.35 11:20 09:15 DATA AcmeInternet --> V.35 11:21 09:16 DATA AcmeInternet --> V.35 11:22 09:17 DATA AcmeInternet --> V.35 11:23 09:18 DATA AcmeInternet --> V.35

11:24 09:19 DATA AcmeInternet --> V.35

2.If DS0 crossconnect settings are correct, skip remaining steps.

NOTE: To change existing DS0 connections, you must first disconnect them before making new connections.

3.Disconnect existing DS0s with the following command:

disconnect <n:ch>

Example: disconnect 25:1-24

Access Navigator - Release 1.8