IBM manual IBM xSeries 350 Type 8682 Hardware Maintenance Manual

Models: 8682

1 174
Download 174 pages 27.1 Kb
Page 122
Image 122

Error Code/Symptom

FRU/Action

 

 

 

201

1.

Run memory diagnostics.

 

(Memory test error, see Memory Settings

2.

DIMM

on page 37) If the server does not have

3.

Memory card

the latest level of BIOS installed, update

4.

System Board

the BIOS to the latest level and run the

 

 

diagnostic program again.

 

 

 

 

 

229

1.

Processor

 

(Cache error)

2.

Optional Processor (if installed)

 

 

 

 

 

289

1.

Run Configuration/Setup

 

(DIMM has been disabled by user or

2.

Disabled DIMM

 

 

system, see Memory Settingson page

 

 

37)

 

 

 

 

 

301

1.

Keyboard

 

(Keyboard or keyboard controller error)

2.

System Board

 

 

 

 

 

303

1.

System Board

 

(Keyboard controller error)

2.

Keyboard

 

 

 

 

 

602

1.

Diskette

 

(Invalid diskette boot record)

2.

Diskette Drive

 

 

 

3.

Cable

 

4.

System Board

 

 

 

604

1.

Run Configuration/Setup and Diagnostics

 

(Diskette drive error)

2.

Diskette Drive

 

 

 

3.

Drive Cable

 

4.

System Board

 

 

 

662

1.

Run Configuration/Setup and Diagnostics

 

(Diskette drive configuration error)

2.

Diskette Drive

 

 

 

3.

Drive Cable

 

4.

System Board

 

 

 

962

1.

Disconnect external cable on parallel port.

 

(Parallel port error)

2.

Run Configuration/Setup

 

 

 

3.

System Board

 

 

 

11XX

1.

Disconnect external cable on serial port.

 

(System board serial port 1 or 2 error)

2.

Run Configuration/Setup

 

 

 

3.

System Board

 

 

 

1162

1.

Disconnect external cable on serial port

 

(Serial port configuration conflict)

2.

Run Configuration/Setup

 

 

 

3.

System board

 

 

 

1200

1.

Processor

 

(processor machine check)

 

 

 

 

 

112IBM xSeries 350 Type 8682: Hardware Maintenance Manual