Table 3. Novell NetWare or IntraNetWare ODI driver messages for the Ethernet controller (continued)

PCNTNW-NW-079

The Multiple Link Interface Driver (MLID) did not initialize MSMTx Free Count.

 

Explanation: The MSMTx Free Count is not initialized correctly.

 

Action: Restart the server. If the problem persists, go to “Starting the diagnostic

 

programs” on page 14 to run the diagnostic programs.

 

 

PCNTNW-NW-086

The driver parameter block is too small.

 

Explanation: The driver parameter block is too small.

 

Action: Restart the server. If the problem persists, go to “Starting the diagnostic

 

programs” on page 14 to run the diagnostic programs.

 

 

PCNTNW-NW-087

The media parameter block is too small.

 

Explanation: The driver media parameter block is too small.

 

Action: Restart the server. If the problem persists, go to “Starting the diagnostic

 

programs” on page 14 to run the diagnostic programs.

 

 

PCNTNW-NW-091

The hardware configuration conflicts.

 

Explanation: You tried to load a new frame type for the existing controller. The

 

hardware assumptions made in doing so are incorrect. This error can also occur if

 

you try to specify a mode (such as, redundancy) that conflicts with another specified

 

mode.

 

Action: Make sure that the hardware configuration matches the software settings.

 

 

PCNTNW-NW-126

The group bit in the node address override was cleared.

 

Explanation: The IEEE address has a group bit that indicates that an address

 

belongs to a group of stations. This bit is used only as a destination address; it

 

cannot be used as a source address. You tried to enter a source address with this bit

 

set. The driver cleared the group bit of the source address.

 

Action: None necessary, message is for information only.

 

 

PCNTNW-NW-127

The local bit in the node address override was set.

 

Explanation: The local bit in the IEEE address format indicates that the addresses

 

are being managed locally. If you use the node address override capabilities of this

 

driver to enter a new address, the local bit must be set. You entered an address

 

without the local bit set. The driver has set the local bit.

 

Action: None necessary, message is for information only.

 

 

PCNTNW-NW-164

The device was not found.

 

Explanation: The driver cannot find an Ethernet controller in the server.

 

Action: Verify that the Ethernet controller is enabled. If the Ethernet controller is

 

enabled, go to “Starting the diagnostic programs” on page 14 to run the diagnostic

 

programs.

 

 

PCNTNW-NW-165

The device was not found at IOADDRESS.

 

Explanation: The Ethernet controller cannot be found at the I/O address specified.

 

Action: The Ethernet controller does not require a parameter for the I/O address.

 

Remove the I/O address parameter.

 

 

PCNTNW-NW-167

PCI scan specified, device not found.

 

Explanation: The driver cannot locate the Ethernet controller on the PCI bus.

 

Action: Verify that the Ethernet controller is enabled. If the problem persists, go to

 

“Starting the diagnostic programs” on page 14 to run the diagnostic programs.

 

 

PCNTNW-NW-180

The DMA parameter is not necessary for PCI device.

 

Explanation: The Ethernet controller does not require a DMA setting.

 

Action: None necessary, message is for information only.

 

 