Table 3. Novell NetWare or IntraNetWare ODI driver messages for the Ethernet controller

PCNTNW-NW-026

The MSM is unable to parse a required custom keyword.

 

Explanation: The user entered an incorrect parameter keyword.

 

Action: Reload the driver using the correct keyword.

 

 

PCNTNW-NW-054

The adapter did not respond to the initialization command.

 

Explanation: The adapter did not respond when the driver tried to initialize it.

 

Action: Verify that the Ethernet controller is enabled. If the Ethernet controller is

 

enabled, go to “Starting the diagnostic programs” on page 14 to run the diagnostic

 

programs.

 

 

PCNTNW-NW-058

The adapter did not respond to the initialization command.

 

Explanation: The interrupt request (IRQ) setting might not be valid or the EEPROM

 

information might be incorrect.

 

Action: Make sure the IRQ settings are correct in the Configuration/Setup Utility

 

program. for information on setting the interrupt requests. If the IRQ settings are

 

correct, go to “Starting the diagnostic programs” on page 14 to run the diagnostic

 

programs.

 

 

PCNTNW-NW-066

The cable might be disconnected from the adapter.

 

Explanation: The cable might be disconnected from the server Ethernet port.

 

Action: Verify that a cable is connected to the Ethernet port.

 

 

PCNTNW-NW-071

The matching virtual adapter could not be found.

 

Explanation: You tried to load another instance of the driver with a different I/O

 

address. This new adapter could not be found.

 

Action: Verify that you installed an IBM 10/100 Fault Tolerant Adapter and make sure

 

that the adapter is seated correctly. If the adapter is seated correctly, go to “Starting

 

the diagnostic programs” on page 14 to run the diagnostic programs.

 

 

PCNTNW-NW-072

A resource tag is unavailable.

 

Explanation: The driver tried to allocate some resources that were not available.

 

Action: Add more memory, or free some memory resources in the server. Then,

 

restart the server.

 

 

PCNTNW-NW-073

Unable to allocate memory

 

Explanation: The driver failed to allocate the memory needed for normal operation.

 

Action: Add more memory, or free some memory resources in the server. Then,

 

restart the server.

 

 

PCNTNW-NW-074

The hardware interrupt cannot be set.

 

Explanation: An attempt was made to initialize a given hardware interrupt. The

 

attempt was not successful.

 

Action: Verify that the Ethernet controller is enabled. If the Ethernet controller is

 

enabled, go to “Starting the diagnostic programs” on page 14 to run the diagnostic

 

programs. If you have an Ethernet adapter installed, make sure that the adapter does

 

not share an IRQ with any other device.

 

 

PCNTNW-NW-075

The Multiple Link Interface Driver (MLID) cannot be registered with the Link

 

Support Layer (LSL).

 

Explanation: An error occurred while the driver was trying to register with the LSL.

 

Action: Check the version of the NetWare or IntraNetWare Operating System. Make

 

sure that this driver is correct for the version of NetWare or IntraNetWare that you are

 

using. Restart the server.

 

 