IBM 8682 manual Fan error messages, Power error messages

Models: 8682

1 174
Download 174 pages 27.1 Kb
Page 129
Image 129
Fan error messages

Message

Action

 

 

 

Power Supply XTemperature Fault

1.

Ensure system is being properly cooled; see

(level-critical; power supply xhad over temperature

 

“Temperature checkout” on page 23

2.

Replace Power Supply X

condition)

 

 

 

System over temperature for CPU X

1.

Ensure system is being properly cooled; see

(level-warning; CPU Xreporting over temperature

 

“Temperature checkout” on page 23

2.

Replace system board.

condition)

 

 

 

 

 

System under recommended CPU Xtemperature

1.

Ambient temperature must be within normal

(level-warning; system reporting under temperature

 

operating specifications; (see “Features and

 

specifications” on page 3).

condition for CPU X)

 

 

 

 

 

 

System over recommended ambient temperature

1.

Ambient temperature must be within normal

 

(level-warning; ambient temperature too warm for safe

 

operating specifications; (see “Features and

 

specifications” on page 3).

system operation)

 

 

 

 

 

 

Fan error messages

Message

Action

 

 

 

Fan Xfault

1.

Check connections to fan X

 

(level-critical; fan Xbeyond recommended RPM

2.

Replace fan X

 

 

range)

 

 

 

 

 

Power error messages

Message

Action

 

 

 

Power supply XDC good fault

1.

Replace power supply X

 

(level-critical; power good signal not detected for power

 

 

supply X)

 

 

 

 

 

Power supply Xfan fault

1.

Replace power supply X

 

(level-critical; fan fault in power supply X)

 

 

 

 

 

Power supply Xfault

1.

See “Power checkout” on page 20

(level-critical; overcurrent condition exists)

 

 

 

 

 

Power supply X12V fault

1.

See “Power checkout” on page 20

(level-critical; overcurrent condition detected)

 

 

 

 

 

Power supply X3.3V fault

1.

See “Power checkout” on page 20

(level-critical; 3.3V power supply Xhad an error)

 

 

 

 

 

Power supply X5V fault

1.

See “Power checkout” on page 20

(level-critical; 5V power supply Xhad an error)

 

 

 

 

 

Power supply current exceeded max spec value

1.

See “Power checkout” on page 20

 

(level-critical; current draw in system is over allowance for

 

 

a single supply)

 

 

 

 

 

Symptom-to-FRU index 119

Page 129
Image 129
IBM 8682 manual Fan error messages, Power error messages