IBM 8682 manual Diagnostic error codes, The Esc key was pressed to abort the test

Models: 8682

1 174
Download 174 pages 27.1 Kb
Page 113
Image 113
Diagnostic error codes

Diagnostic error codes

Note: In the following error codes, if XXX is 000, 195, or 197 do not replace a

FRU. The description for these error codes are:

000The test passed.

195The Esc key was pressed to abort the test.

197This is a warning error and may not indicate a hardware failure. For all error codes, replace/follow the FRU/Action indicated.

Error Code/Symptom

FRU/Action

 

 

 

001-XXX-000

1.

System Board

 

(Failed core tests)

 

 

 

 

 

001-XXX-001

1.

System Board

 

(Failed core tests)

 

 

 

 

 

001-250-000

1.

System Board

 

(Failed System Board ECC)

 

 

 

 

 

001-250-001

1.

System Board

 

(Failed System Board ECC)

 

 

 

 

 

005-XXX-000

1. Video Adapter (if installed)

 

(Failed Video test)

2.

System Board

 

 

 

 

 

011-XXX-000

1.

System Board

 

(Failed COM1 Serial Port test)

 

 

 

 

 

011-XXX-001

1.

System Board

 

(Failed COM2 Serial Port test)

 

 

 

 

 

014-XXX-000

1.

System Board

 

(Failed Parallel Port test)

 

 

 

 

 

015-XXX-001

1.

System Board.

 

(Failed USB test)

 

 

 

 

 

015-XXX-015

1. Make sure parallel port is not disabled.

 

(Failed USB External Loopback test)

2. Re-run USB External Loopback test.

 

 

 

3.

System board.

 

 

 

015-XXX-198

1. Remove USB devices from USB1 and USB2.

 

(USB device connected during USB test)

2. Re-run test.

 

 

 

3.

System Board.

 

 

 

020-XXX-000

1.

System Board

 

(Failed PCI Interface test)

 

 

 

 

 

020-XXX-001

1. PCI Hot-Swap Latch Assembly

 

(Failed Hot-Swap Slot 1 PCI Latch test)

2.

System Board

 

 

 

 

 

Symptom-to-FRU index 103