ERserver
Hardware Maintenance Manual
IBM xSeries 350 Type
Page
ERserver
Hardware Maintenance Manual
IBM xSeries 350 Type
Sixth Edition September
About this manual
Important safety information
Online support
iv IBM xSeries 350 Type 8682 Hardware Maintenance Manual
Contents
vi IBM xSeries 350 Type 8682 Hardware Maintenance Manual
FRU information service only
Symptom-to-FRU index
Parts listing, Type
Contents
viii IBM xSeries 350 Type 8682 Hardware Maintenance Manual
General checkout
1. IS THE SYSTEM PART OF A CLUSTER?
Checkout procedure
3. DID YOU RECEIVE BOTH OF THE CORRECT RESPONSES?
Features and specifications
v Hot-swap power supplies
General information
v Microprocessor
v Size 4 U
v Integrated functions
v Acoustical noise emissions
v Environment
Server features
Reliability, availability, and serviceability
v Hot-swap hard disk drives v Active PCI hot-plug adapter slots
Start the server
Controls and indicators
Information LED panel
10 IBM xSeries 350 Type 8682 Hardware Maintenance Manual
Diagnostics
Diagnostic tools overview
v POST beep codes, error messages, and error logs
v Diagnostic programs and error messages
POST error messages
Event/error logs
ServerGuide error symptoms
POST beep codes
Diagnostic programs and error messages
date
Starting the diagnostic programs
Text messages
Function Name
Result
Diagnostic error message tables
Viewing the test log
Light path diagnostics
Power supply LEDs
The following table describes the ac and dc power LEDs
AC power LED
DC power LED
Description and action
Diagnostic panel LEDs
Microprocessor fault
Memory fault
PCI bus A fault
Light Path Diagnostics
Power checkout
Recovering BIOS
Replacing the battery
7. Remove the battery
Temperature checkout
Diagnosing errors
Troubleshooting the Ethernet controller
Network connection problems
Ethernet controller troubleshooting chart
Ethernet controller messages
Novell NetWare or IntraNetWare server ODI driver messages
26 IBM xSeries 350 Type 8682 Hardware Maintenance Manual
PCNTNW-NW-079
Network driver interface specification 2.01 OS/2 driver messages
Table 4. NDIS 2.01 OS/2 driver messages for the Ethernet controller
NDIS 4.0 Windows NT driver messages
Table 5. NDIS Windows NT driver messages for the Ethernet controller
UNIX messages
UNIX LLI driver, and suggested actions to resolve each problem
Table 6. UNIX LLI driver messages for the Ethernet controller
Page
32 IBM xSeries 350 Type 8682 Hardware Maintenance Manual
Configuring the server
Using the Configuration/Setup Utility program
Starting the Configuration/Setup Utility program
v Configuration/Setup Utility
Choices available from the Configuration/Setup main menu
v System Summary
v System Information
Product Data
Power-on Password
Administrator Password
v Date and Time
v System Security
v Advanced Setup
Processor Serial Number Access
System Partition Visibility
Core Chipset Control
Using passwords
Memory Settings
Hot Swap PCI Slot Power Control
v System Service Processor Settings
Administrator password
Power-on password
Table 7. Jumper J15 on the system board
Using the SCSISelect utility program
Starting the SCSISelect utility program
v Configure/View Host Adapter Settings
Boot Device Options
SCSI Device Configuration
Advanced Configuration Options
Installing options
Expanded view of the xSeries
Component locations
System board component locations
120 MM fan J49 Advanced System Management processor J69, J68, J67
Table 9. Jumpers J14 and J15 on the system board
Jumper name
Description
Table 10. Jumper setback table
Microprocessor speed jumpers
System board LED locations
Diagnostic panel LEDs
Microprocessor fault
Memory fault
PCI bus A fault
Memory board component locations
Error LEDs
Error LEDs Memory slot
48 IBM xSeries 350 Type 8682 Hardware Maintenance Manual
Power LED
Advanced System Management Interconnect board component locations
Advanced System Management
Working inside the server with the power on
Before you begin
System reliability considerations
50 IBM xSeries 350 Type 8682 Hardware Maintenance Manual
Handling static-sensitive devices
52 IBM xSeries 350 Type 8682 Hardware Maintenance Manual
≥55 kg 121.2 lb
Removing the server top cover and bezel
Working with adapters
Installing a hot-plug adapter
Power-on light
Expansion-slot cover Adapter retention Tab latch
Adapter retention cover Plastic dividers
Cabling example for the ServeRAID adapter
56 IBM xSeries 350 Type 8682 Hardware Maintenance Manual
To cable the ServeRAID adapter 1. Turn off the server
Attention When you route the SCSI cable, observe the following
Installing internal drives
Internal drive bays
Hard disk drive component locations
SCSI hot-swap hard disk drive connector
60 IBM xSeries 350 Type 8682 Hardware Maintenance Manual
Hard disk drive activity light green
The following illustration shows the rear connectors on the hot-swap-drive backplane before the repeater card is installed, as viewed from the rear of the server
Installing a hot-swap hard disk drive
Installing memory-module kits
Before you begin v Review “Before you begin” on page
6. Install the memory board assembly
Installing a microprocessor kit
66 IBM xSeries 350 Type 8682 Hardware Maintenance Manual
33 MHz J50
68 IBM xSeries 350 Type 8682 Hardware Maintenance Manual
Changing jumper positions
Three-pin jumper blocks
Installing a hot-swap power supply
Filler panel AC power light DC power light
Power supply
70 IBM xSeries 350 Type 8682 Hardware Maintenance Manual
Installing a 3-Pack Ultra160 Hot-Swap Expansion Kit
To install a 3-Pack Ultra160 Hot-Swap Expansion Kit
Replacing a hot-swap fan
Hot-swap fans
Completing the installation
Installing the server top cover and bezel
Updating the server configuration
Connecting external options
Parallel port
Input/output ports
Viewing or changing the parallel-port assignments
Parallel port connector
Video port
Keyboard port
Auxiliary-device pointing device port
Ultra160 SCSI ports
Setting SCSI IDs
SCSI connector pin-number assignments
SCSI cabling requirements
Standard
Serial ports
Table 18. 68-pin SCSI connector pin-number assignments
Serial-port connectors
Universal Serial Bus ports
Viewing or changing the serial-port assignments
USB cables and hubs
USB-port connectors
Configuring the Ethernet controller
Ethernet port
Failover for redundant Ethernet
Windows NT Server
Windows NT Server hot-plug setup
1. IBM PCI Hotplug for Windows NT 4.0 Failover DMI Agent
Windows NT Server failover setup
To install the IBM PCI Hotplug for Windows NT 4.0 Failover DMI Agent
Ethernet port connector
IntraNetWare
Advanced System Management ports
Table 21. Ethernet RJ-45 connector pin-number assignments
Cabling the server
88 IBM xSeries 350 Type 8682 Hardware Maintenance Manual
LED switch card
FRU information service only
Before you begin
90 IBM xSeries 350 Type 8682 Hardware Maintenance Manual
Four-fan housing
Before you begin
FRU information service only
Dual fan mount assembly with cable
Before you begin
92 IBM xSeries 350 Type 8682 Hardware Maintenance Manual
Service processor card assembly
Before you begin
PCI switch card
Before you begin
94 IBM xSeries 350 Type 8682 Hardware Maintenance Manual
Power backplane assembly
Before you begin
System board assembly with backerplate
Before you begin
96 IBM xSeries 350 Type 8682 Hardware Maintenance Manual
Symptom-to-FRU index
Beep symptoms
98 IBM xSeries 350 Type 8682 Hardware Maintenance Manual
Symptom-to-FRU index
No beep symptoms
100 IBM xSeries 350 Type 8682 Hardware Maintenance Manual
Diagnostic panel error LEDs
102 IBM xSeries 350 Type 8682 Hardware Maintenance Manual
FRU. The description for these error codes are 000 The test passed
Diagnostic error codes
195 The Esc key was pressed to abort the test
104 IBM xSeries 350 Type 8682 Hardware Maintenance Manual
Error Code/Symptom
106 IBM xSeries 350 Type 8682 Hardware Maintenance Manual
Error Code/Symptom
Error symptoms
108 IBM xSeries 350 Type 8682 Hardware Maintenance Manual
Setup
Setup
Get “time out” or “Unknown host” errors
Be sure you have access to the Internet through FTP directly
Power supply LED errors
POST error codes
Error Code/Symptom
112 IBM xSeries 350 Type 8682 Hardware Maintenance Manual
Error Code/Symptom
114 IBM xSeries 350 Type 8682 Hardware Maintenance Manual
Error Code/Symptom
ServeRAID
Manual for the particular RAID adapter in the system being serviced
I2C bus fault messages
Temperature error messages
SCSI error codes
118 IBM xSeries 350 Type 8682 Hardware Maintenance Manual
Fan error messages
Power error messages
Voltage related system shutdown
System shutdown
120 IBM xSeries 350 Type 8682 Hardware Maintenance Manual
Temperature related system shutdown
DASD checkout
CPU checkout
level-critical specified processor reported internal error and
Undetermined problems
Parts listing, Type
System
xSeries 350, Type 8682 models 1RY 2RY 4RY 5RY 6RY
Index
FRU No
Power cords
Keyboards
37L0350
6952301
Samoa
Safety information
Related service information
General safety
Electrical safety
Safety inspection guide
Handling electrostatic discharge-sensitive devices
Grounding requirements
Safety notices multi-lingual translations
132 IBM xSeries 350 Type 8682 Hardware Maintenance Manual
Do not
Statement
Importante
Instrução PERIGO
Para Conectar
Para Desconectar
Instrução PRECAUCIÓN
Instrução CUIDADO
PERIGO
Instrução
≥18 kg 39.7 lb
≥32 kg 70.5 lb
CUIDADO
Related service information
138 IBM xSeries 350 Type 8682 Hardware Maintenance Manual
Related service information
140 IBM xSeries 350 Type 8682 Hardware Maintenance Manual
Related service information
142 IBM xSeries 350 Type 8682 Hardware Maintenance Manual
Related service information
144 IBM xSeries 350 Type 8682 Hardware Maintenance Manual
Notice n DANGER
Connexion
Déconnexion
Notice n
Notice n
Wichtig
Hinweis VORSICHT
Kabel anschlieβen
Kabel lösen
Die Batterie nicht v mit Wasser in Berührung bringen
≥18 kg
150 IBM xSeries 350 Type 8682 Hardware Maintenance Manual
Importante
Avviso PERICOLO
Per collegare
Evitare di v Gettarla o immergerla in acqua
Avviso
≥18 kg
≥32 kg
ATTENZIONE
Related service information
154 IBM xSeries 350 Type 8682 Hardware Maintenance Manual
Related service information
156 IBM xSeries 350 Type 8682 Hardware Maintenance Manual
Importante
Declaración PELIGRO
Para la conexin
Para la desconexiín
No realice las acciones siguientes v Arrojarla al agua o sumergirla
Declaración
PRECAUCIÓN
Declaración PRECAUCIÓN
Declaración PRECAUCIÓN
Problem determination tips
Notices
Trademarks
Eserver
162 IBM xSeries 350 Type 8682 Hardware Maintenance Manual
Page
Part Number 24P2905 File Number Printed in U.S.A
1P P/N 24P2905