IBM manual IBM xSeries 350 Type 8682 Hardware Maintenance Manual

Models: 8682

1 174
Download 174 pages 27.1 Kb
Page 116
Image 116

Error Code/Symptom

FRU/Action

 

 

 

201-XXX-0NN

1.

DIMM Location J1-J16

 

(Failed Memory test, see Memory

2.

Memory card

 

 

Settingson page 37) NN = DIMM

 

 

location.

 

 

 

 

 

201-XXX-999

1. See error text for failing DIMMs

 

(Multiple DIMM failure, see error text.)

2.

Memory card

 

 

 

 

 

202-XXX-001

1.

Microprocessor CPU 1

 

(Failed System Cache test)

 

 

 

 

 

202-XXX-002

1.

Microprocessor CPU 2

 

(Failed System Cache test)

 

 

 

 

 

202-XXX-003

1.

Microprocessor CPU 3

 

(Failed System Cache test)

 

 

 

 

 

202-XXX-004

1.

Microprocessor CPU 4

 

(Failed System Cache test)

 

 

 

 

 

206-XXX-000

1.

Cable

 

(Failed Diskette Drive test)

2.

Diskette Drive

 

 

 

3.

System Board

 

 

 

215-XXX-000

1. CD-ROM Drive Cables

 

(Failed IDE CD-ROM test)

2. CD-ROM Drive

 

 

 

3.

System Board

 

 

 

217-XXX-000

1.

Fixed Disk 1

 

(Failed BIOS Fixed Disk test)

 

 

Note: If RAID is configured, the fixed

 

 

disk number refers to the RAID logical

 

 

array.

 

 

 

 

 

217-XXX-001

1.

Fixed Disk 2

 

(Failed BIOS Fixed Disk test)

 

 

Note: If RAID is configured, the fixed

 

 

disk number refers to the RAID logical

 

 

array.

 

 

 

 

 

217-XXX-002

1.

Fixed Disk 3

 

(Failed BIOS Fixed Disk test)

 

 

Note: If RAID is configured, the fixed

 

 

disk number refers to the RAID logical

 

 

array.

 

 

 

 

 

217-XXX-003

1.

Fixed Disk 4

 

(Failed BIOS Fixed Disk test)

 

 

Note: If RAID is configured, the fixed

 

 

disk number refers to the RAID logical

 

 

array.

 

 

 

 

 

106IBM xSeries 350 Type 8682: Hardware Maintenance Manual

Page 116
Image 116
IBM manual IBM xSeries 350 Type 8682 Hardware Maintenance Manual