FRU information (service only)

FRU information (service only)

Field Replacement Units (FRUs) should be replaced by qualified service personnel only.

LED switch card

Before you begin:

vRead “Safety information” on page 127

vReview the information in “Before you begin” on page 50

Holding screws

LED switch card

To remove the LED switch card, do the following:

1.Power-off the server, if it is on.

2.Unplug the server.

3.Remove the top cover (see “Removing the server top cover and bezel” on page 53).

4.Disconnect the switch card cables.

5.Remove the 4 holding screws.

6.Lift the switch card out of the server.