Carrier Access user manual Access Navigator Release August 18-141

Models: Access Navigator

1 704
Download 704 pages 57.28 Kb
Page 597
Image 597

CLI Language Reference

CLI Command List

Message:

Settings for DS1 9:

CA DS1# 9

 

 

 

Circuit ID:

 

 

 

Up/Down:

DOWN

 

 

 

Framing:

ESF

 

 

 

Line Coding:

B8ZS

 

 

 

Type:

DROP

 

 

 

Clock Source:

NORMAL

 

 

 

Line Build Out:

CSU ATTEN FOR -15dB

 

Loop Code Detection:

ON

 

 

 

Loop Back:

OFF

 

 

 

Line Termination ID:

0 (for switch DS1s only)

 

Remote Device MGMT:

CA IP 192.168.201.1

 

PPHONE Call Connection:

Enabled

 

 

 

FDL Type:

None

 

 

 

Send Code:

NONE

 

1 hour

1 day

Performance Thresholds:

15 min.

unavailable seconds:

--------

-------

------

 

0

0

0

severely errored seconds:

 

0

0

0

errored seconds:

 

0

0

0

sev. errored frame seconds:

0

0

0

degraded minutes:

 

0

0

0

linecode violations:

 

0

0

0

NOTE: The Performance Thresholds are threshold values, not error counts.

Description:

Item

Description

 

 

Circuit ID

Circuit identifier set by user for the DS1 number.

 

 

Up/Down

Link service status: UP, DOWN.

 

 

Framing

D4 (SF), ESF, SLC96 (S4).

 

 

Line Coding

AMI, B8ZS.

 

 

Type

DROP, GROOM, SWITCH. Switch type appears only with GR-

 

303 option.

 

 

Clock Source

NORMAL, LOOP.

 

 

Line Build Out

DSX-1 equalization (ft.), CSU attenuation (dB).

 

 

Loop Code Detection

ON, OFF.

 

 

Loop Back

OFF, LINE, PAYLOAD.

 

 

Line Termination ID

Line termination identifier, 1 to 28, set by user (used by GR-303

 

only.

 

 

Remote Device MGMT

NONE, CAFDL, CAIP <ipaddress>, DS1 <n>.

 

 

Access Navigator - Release 1.8

August 2003

18-141

Page 597
Image 597
Carrier Access user manual Access Navigator Release August 18-141