CLI Language Reference

CLI Command List

Set DS1 ID

Purpose: Sets the carrier’s DS1 circuit identifier string.

Security: Level 2 (operator)

Syntax: set ds1 <n> id <"id">

Field

n

"id"

Description

DS1 number, 1 to 32.

A text string of up to 30 characters enclosed in quote marks.

Example: set ds1 9 id "CA ds1 #9"

Set DS1 LBO

Purpose: Sets the DS1 line buildout (lbo) to the required DSX-1 equalization or CSU attenuation.

Security: Level 2 (operator)

Syntax: set ds1 <n> lbo <setting>

Field

n

setting

Description

DS1 number, 1 to 32, or a range of numbers such as 2-8.

The line buildout setting is a number, from 1 to 9.

1– Set DSX-1 equalization for 0-133 ft.

2– Set DSX-1 equalization for 133-266 ft.

3– Set DSX-1 equalization for 266-399 ft.

4– Set DSX-1 equalization for 399-533 ft.

5– Set DSX-1 equalization for 533-666 ft.

6– Set CSU attenuation for LBO of 0dB.

7– Set CSU attenuation for LBO of -7.5dB.

8– Set CSU attenuation for LBO of -15dB.

9– Set CSU attenuation for LBO of -22.5dB.

Example: set ds1 9 lbo 8

Set DS1 Line Loopup

Purpose: Provides line loopback to verify that the DS1 signal is reaching the Access Navigator’s Quad T1 Framer card. The line loopup command creates a connection inside the Line Interface Unit (LIU), causing it to loop the DS1 receive (input) back to the transmit (output). See Figure 18-28.

NOTE: For normal operation, the loopback must be disabled (loopdown).

Access Navigator - Release 1.8

August 2003

18-109

Page 565
Image 565
Carrier Access Access Navigator user manual Set DS1 ID, Set DS1 LBO, Set DS1 Line Loopup