CLI Language Reference

CLI Command List

Set Remote T1Drop Framing

CAUTION! IF THE T1 DROP ON THE ACCESS BANK II WILL BE USED, THE T1 DROP CIRCUIT OR LOOPBACK MUST BE INSTALLED BEFORE DOWNLOADING THE CONFIGURATION, OTHERWISE THE RESULTING AIS ALARM WILL TAKE DOWN THE FDL COMMUNICATIONS LINK UNTIL THE CIRCUIT IS INSTALLED AND THE ALARM CLEARED

Purpose: Sets the T1 Drop framing type to D4 or ESF. (T1 PBXs generally use D4 framing; T1 routers may use D4 or ESF.)

The Access Bank II provides a second T1 port, called the T1 Drop, for connection to a T1 PBX or T1 router. You can connect one or more DS0s to the T1 Drop, using a fractional interface. The Access Navigator automatically assigns DS0s to the T1 drop in sequential order, starting with T1 Drop DS0 #1. If the router does not have automatic rate sensing, it will have to be programmed for the proper data rate. Use the show remote command to display the current settings stored in the Access Navigator’s data base).

Security: Level 2 (operator)

Syntax: set remote <n> t1drop framing <d4esf>

Field

Description

 

 

n

DS1 number, 1 to 32.

 

 

 

d4

Set T1

Drop to D4 framing.

 

 

 

esf

Set T1

Drop to ESF framing.

 

 

 

Example: set remote 9 t1drop framing d4

18-122

August 2003

Access Navigator - Release 1.8

Page 578
Image 578
Carrier Access Access Navigator user manual Set Remote T1Drop Framing, Syntax set remote n t1drop framing d4esf