Electrical Installation

Attach Ferrite Bead RF Suppressor

Attach Ferrite Bead RF Suppressor

CAUTION! SHIELDED RS-232CABLE WITH FERRITE BEAD RF SUPPRESSOR IS REQUIRED FOR COMPLIANCE WITH NEBS 1089 EMI/EMC AND FCC REQUIREMENT

PART 15, TO PREVENT RADIO FREQUENCY INTERFERENCE WITH OTHER EQUIPMENT.

1.Position ferrite bead for most convenient cable dressing and wire tying. Location is not critical.

2.Open the snap-on ferrite beads along hinge cover (see Detail A in Figure 6-10).

3.Loop RS-232 cable so that cable passes through center of ferrite bead twice (see Detail B).

4.Fold ferrite bead hinge covers together over RS-232 cable. Press covers together until they snap together.

RS-232 CLI

Management

Connector

Open

Detail A

Shielded

RS-232

Ferrite

Bead

Detail B

Cable

Figure 6-10. Attaching Ferrite Bead RF Suppressor

6-20