Carrier Access Access Navigator user manual Example Set ds1 10 loopdetect on

Models: Access Navigator

1 704
Download 704 pages 57.28 Kb
Page 207
Image 207

Provision DCS Service

Provision “Groom” DS1 Circuits to Network

5.Set groom DS1 line code to AMI or B8ZS with the following command: set ds1 <n> linecode <amib8zs>

Example:

set ds1 10 linecode b8zs

6.Set groom DS1 circuit ID with the following command: set ds1 <n> id <"id">

Example: set ds1 10 id "Acme Corp DS1#5"

The ID may contain up to 20 characters and must be enclosed in quote marks.

NOTE: DS1 clock must be set to “normal” for normal operation.

7.Set groom DS1 clock source to normal or loop with the following command: set ds1 <n> clock <normalloop>

Example:

set ds1 10 clock normal

8.Set groom DS1 line buildout (lbo) to required DSX-1 equalization or CSU attenuation with the following command:

set ds1 <n> lbo <setting>

Example:

set ds1 10 lbo 3

The setting is a number from 1 to 9, and is defined as follows:

Setting Definition

1Set DSX-1 equalization for 0-133 ft.

2Set DSX-1 equalization for 133-266 ft.

3Set DSX-1 equalization for 266-399 ft.

4Set DSX-1 equalization for 399-533 ft.

5Set DSX-1 equalization for 533-666 ft.

6Set CSU attenuation for LBO of 0dB.

7Set CSU attenuation for LBO of -7.5dB.

8Set CSU attenuation for LBO of -15dB.

9Set CSU attenuation for LBO of -22.5dB.

9.Set groom DS1 loop request code detection to on or off with the following command:

set ds1 <n> loopdetect <onoff>

Example:

set ds1 10 loopdetect on

Access Navigator - Release 1.8

August 2003

9-13

Page 207
Image 207
Carrier Access Access Navigator user manual Example Set ds1 10 loopdetect on