Philips PT-LB51SU Replacing the Lamp unit, Care and Replacement, Before replacing the Lamp unit

Models: PT-LB51SU

1 62
Download 62 pages 50.41 Kb
Page 41
Image 41
Care and Replacement

Care and Replacement

Replacing the Lamp unit

Before replacing the Lamp unit

Disconnect the power cord plug from the wall outlet.

Make sure the Lamp unit and the surroundings are cooled enough. Prepare a Phillips-head screwdriver.

Contact an Authorised Service Center to purchase a replacement Lamp unit (ET-LAB50).

When the projector is mounted in the ceiling, do not work directly under the projector or put your face closer to the projector.

NOTE:

Prior to replacing the lamp unit, allow it to cool down to prevent the risk of burns, damage and other hazards.

Do not attempt replacement with an unauthorised lamp unit.

When to replace the Lamp unit

The Lamp unit is a consumable product. Even when the full life of the bulb has not been exhausted, the brightness of the light will gradually decline. Therefore periodic replacement of the lamp is necessary. The intended lamp replacement interval is 2 000 hours, but it is possible that the lamp may need to be replaced earlier due to variables such as a particular lamp’s characteristics, usage conditions and the installation environment.

Early preparation for lamp replacement is encouraged.

The lamp will automatically shut off after approximately 10 minutes when 2 000 hours of use have been reached because of a much greater chance of it exploding after this time.

On screen

LAMP indicator

Indication

REPLACE LAMP

Over 1 800 hours

REPLACEMENT LAMP” is displayed on

 

the upper left of the screen for 30 seconds.

 

 

 

 

 

 

 

REPLACEMENT LAMP” is displayed on

Illuminates RED.

 

the upper left of the screen, and it will stay

Over 2 000 hours

 

until you respond.

 

 

 

 

To clear the screen, press any button.

 

NOTE:

The usage hours explained above are for when “LAMP POWER” in the “OPTION” menu has been set to “STANDARD” and when “AI” in the “PICTURE” menu has been set to “OFF”. If “LAMP POWER” is set to ECO-MODE”, or “AI” is set to “ON”, the life of the lamp can be extended.

While 2 000 hours is the intended replacement interval, it is not a period of time covered by warranty.

Replacement procedure

NOTE:

If the lamp usage time has passed 2 000 hours (when “LAMP POWER” has een set to “STANDARD” and when “AI” has been set to “OFF”), the projector will switch to standby mode after approximately 10 minutes of operation. The steps 7 to 12 should thus be completed within 10 minutes.

1.Disconnect the Power cord from the projector (See “Power cord” on page 20), and check that the area around the Lamp unit has cooled down.