Compatibility
Table 4 lists compatible tools, Operating Systems, and controllers used over the Zone Bus and N2 Bus with the CVTPRO converter.
Table 4: Compatibility Chart
Compatible controllers include the Air Handling Unit (AHU), Unitary Controller (UNT), Variable Air Volume Controller (VAV), Network Dialer Module (NDM), and VMA.
Tool | Bus | Operating System | Compatible Controller |
HVAC PRO Software (part of | N2 Bus | Windows 98 SE/Windows NT1/ | AHU1xx |
| Windows 2000PE2 OS | UNT1xx | |
| Zone Bus | Windows 98 SE/Windows 2000PE2, 3 | UNT11xx |
|
| OS | VAV1xx |
|
|
| |
|
|
| VMA14x0 |
| Zone Bus | Windows NT1 | VMA14x0* |
VBT1400 | Zone Bus | Palm Personal Digital Assistant (PDA) | VMA14x0 |
|
| with OS Version 3.5 or later |
|
VBT1200 | Zone Bus | Palm PDA with OS Version 2.x or later | VMA12x0 |
N2 Bus | Windows 98 SE/Windows NT1/ | ||
Configuration Tool (part of |
| Windows 2000PE2 OS | |
|
| XT9100 (XP91xx) | |
|
|
| |
|
|
| |
XTM Configuration Tool | N2 Bus | Windows 98 SE/1Windows NT1/ | |
|
| Windows 2000PE2 OS |
|
NDM Configuration Tool | N2 Bus | Windows 98 SE/ Windows NT1/ | NDM |
|
| Windows 2000PE2 OS |
|
Note: The CVTPRO converter is not compatible with Zone Terminal Units (ZTUs). For ZTUs, use the
1For proper CVTPRO converter operation when running on Windows NT OSs, Service Pack 6 must be installed.
2For proper CVTPRO converter operation when running on Windows 2000 OSs, use the Professional Edition only, and Service Pack 2 must be installed.
3On Zone Bus applications running on Windows 2000 OSs, HVAC PRO Version 8.04B or later must also be installed.
*When using the VMA14x0 with HVAC PRO software (versions prior to Version 8.04B only) over the Zone Bus with Windows NT OSs, a Device Conflict box appears whenever the user attempts an operation (for example, upload or download). To bypass the box, select Yes or No and the box disappears. The selected operation continues as expected.
Battery Power Recommendations
The CVTPRO converter requires two
AAAalkaline type batteries on N2 Bus applications (when the External Power Adapter is not used). Battery life varies depending on the N2 Bus load, ambient temperature and type of batteries. See Table 5 and observe the following guidelines.
•Always have a spare set of new batteries on hand.
•When performing long downloads with the CVTPRO converter, use the External Power Adapter instead of batteries.
Table 5: *Typical Battery Life in CVTPRO Converter
AAA Battery: | Battery Life |
Manufacturer | |
and Model/Type |
|
Duracell® CopperTop | |
Eveready® Energizer Max® |
*using a CVTPRO converter in continuous operation on a fully loaded N2 Bus at room temperature (70°F [21°C])