Johnson Controls AS-CVTPROx00-1 manual Compatibility

Models: AS-CVTPROx00-1

1 6
Download 6 pages 9.35 Kb
Page 5
Image 5
Compatibility

Compatibility

Table 4 lists compatible tools, Operating Systems, and controllers used over the Zone Bus and N2 Bus with the CVTPRO converter.

Table 4: Compatibility Chart

Compatible controllers include the Air Handling Unit (AHU), Unitary Controller (UNT), Variable Air Volume Controller (VAV), Network Dialer Module (NDM), and VMA.

Tool

Bus

Operating System

Compatible Controller

HVAC PRO Software (part of

N2 Bus

Windows 98 SE/Windows NT1/

AHU1xx

M-Tool Release 5.0 or later)

 

Windows 2000PE2 OS

UNT1xx

 

Zone Bus

Windows 98 SE/Windows 2000PE2, 3

UNT11xx

 

 

OS

VAV1xx

 

 

 

 

 

 

VMA14x0

 

Zone Bus

Windows NT1

VMA14x0*

VBT1400

Zone Bus

Palm Personal Digital Assistant (PDA)

VMA14x0

 

 

with OS Version 3.5 or later

 

VBT1200

Zone Bus

Palm PDA with OS Version 2.x or later

VMA12x0

GX-9100 Software

N2 Bus

Windows 98 SE/Windows NT1/

DT-9100

Configuration Tool (part of

 

Windows 2000PE2 OS

DX-9100

M-Tool Release 5.0 or later)

 

 

XT9100 (XP91xx)

 

 

 

 

 

 

XTM-905 (XPx-xxx)

XTM Configuration Tool

N2 Bus

Windows 98 SE/1Windows NT1/

XTM-105 (XPx-xxx)

 

 

Windows 2000PE2 OS

 

NDM Configuration Tool

N2 Bus

Windows 98 SE/ Windows NT1/

NDM

 

 

Windows 2000PE2 OS

 

Note: The CVTPRO converter is not compatible with Zone Terminal Units (ZTUs). For ZTUs, use the CBLPRO-2 converter. See the Auxiliary Gear Technical Bulletin (LIT-6363080)for details on Johnson Controls® converters.

1For proper CVTPRO converter operation when running on Windows NT OSs, Service Pack 6 must be installed.

2For proper CVTPRO converter operation when running on Windows 2000 OSs, use the Professional Edition only, and Service Pack 2 must be installed.

3On Zone Bus applications running on Windows 2000 OSs, HVAC PRO Version 8.04B or later must also be installed.

*When using the VMA14x0 with HVAC PRO software (versions prior to Version 8.04B only) over the Zone Bus with Windows NT OSs, a Device Conflict box appears whenever the user attempts an operation (for example, upload or download). To bypass the box, select Yes or No and the box disappears. The selected operation continues as expected.

Battery Power Recommendations

The CVTPRO converter requires two (user-supplied)

AAAalkaline type batteries on N2 Bus applications (when the External Power Adapter is not used). Battery life varies depending on the N2 Bus load, ambient temperature and type of batteries. See Table 5 and observe the following guidelines.

Always have a spare set of new batteries on hand.

When performing long downloads with the CVTPRO converter, use the External Power Adapter instead of batteries.

Table 5: *Typical Battery Life in CVTPRO Converter

AAA Battery:

Battery Life

Manufacturer

and Model/Type

 

Ray-O-Vac® Industrial Plus

4-1/2 hours

Duracell® CopperTop

5-1/2 hours

Eveready® Energizer Max®

6-1/2 hours

*using a CVTPRO converter in continuous operation on a fully loaded N2 Bus at room temperature (70°F [21°C])

AS-CVTPROx00-1Zone Bus/N2 Bus Interface Converter Installation Instructions 5

Page 5
Image 5
Johnson Controls AS-CVTPROx00-1 manual Compatibility