6.4 Troubleshooting Abnormal Burner Operation

PROBLEM

PROBABLE CAUSES

CORRECTIVE ACTION

Fryer is operating

 

Shut the fryer down and clean the gas

normally, but flames

Obstructed gas valve vent tube.

valve vent tube in accordance the

are rolling out of the

 

instructions on Page 5-4 of this

front of the burner.

 

manual.

6.5

Troubleshooting the Built-In Filtration System

 

 

 

 

 

 

PROBLEM

PROBABLE CAUSES

CORRECTIVE ACTION

 

 

 

A. If the pump runs normally after

 

 

A. Thermal overload switch has

resetting the thermal overload

 

 

switch, the pump was overheated.

 

 

tripped on an overheated motor.

 

 

 

 

 

Test: If the pump stopped

Always filter with the cooking

 

 

oil/shortening at or near frying

 

 

suddenly during the filtering

 

 

temperature.

 

 

process, especially if after several

 

 

 

 

 

filtering cycles, the pump motor

Allow the pump motor to cool off

 

 

has probably overheated. Place

 

 

for about ten minutes after

 

 

the filter handle in the OFF

 

 

filtering two full frypots one after

 

 

position, allow the pump to cool

 

 

the other.

 

 

for at least 45 minutes, and then

Pump won’t start.

 

press the reset button on the pump

Check the filter paper between

 

 

motor. Attempt to activate the

 

OR

filterings. Replace the paper if

 

pump.

 

there is a large accumulation of

 

 

 

Pump stops during

 

sediment.

B. Failed filter handle microswitch.

 

 

filtering.

 

 

 

Test: If this is a multi-pot fryer,

B. If the switch is loose, tighten the

 

 

attempt to operate the pump using

 

 

a different handle. If the pump

nuts and bolts holding it in place,

 

 

starts, the handle microswitch is

ensuring that when the handle is

 

 

either out of alignment or has

placed in the ON position, the

 

 

failed.

lever on the microswitch is

 

 

When the handle is placed in the

pressed firmly against the switch.

 

 

 

 

 

ON position, the lever on the

If the switch has failed, call

 

 

microswitch should be firmly

FASC.

 

 

pressed against the switch. If so,

 

 

 

the switch has failed. If not, the

 

 

 

switch is loose and/or misaligned.

 

 

 

Continued on