Frymaster 47 Series Burner will not, light, Solid state analog, controller power and, mode

Models: 47 Series

1 44
Download 44 pages 48.19 Kb
Page 37
Image 37
Burner will not

6.2Troubleshooting Fryers with Solid State (Analog), Digital, or CM III Controllers or Basket Lift Timers

PROBLEM

PROBABLE CAUSES

 

CORRECTIVE ACTION

 

A. Pilot not lit (units w/pilot ignition

A. Light pilot per instructions in

 

only).

 

Chapter 3 of this manual.

 

B. Drain valve open.

B. Verify that drain valve is fully

 

 

closed.

 

 

 

 

C. No electrical power to unit.

C. Verify that unit is plugged in and

 

 

that circuit breaker is not tripped.

 

 

 

 

 

D. Verify that the gas line quick

 

 

 

disconnect is properly connected,

Burner will not

D. No gas being supplied to unit.

 

that any cutoff valves between the

 

fryer and the gas main are open,

light.

 

 

and that the main gas cutoff valve

 

 

 

is open.

 

E. Blown fuse on ignition module or

E. Replace fuse per instructions in

 

interface board (units w/electronic

 

Section 6.6 of this manual.

 

ignition only).

 

 

 

 

F.

If available, substitute controller

 

 

 

known to be good for suspect

 

F. Failed controller.

 

controller. If fryer operates

 

 

 

normally, order replacement

 

 

 

controller from FASC.

Solid state (analog)

 

 

 

controller power and

 

If available, substitute controller

trouble lights on, but

 

heat light is not,

 

known to be good for suspect

 

Failed controller.

controller. If fryer operates

OR

 

normally, order replacement

LED display shows

 

controller from FASC.

 

 

 

.

 

 

 

 

 

If available, substitute controller

Unit stays in melt

 

known to be good for suspect

Failed controller.

controller. If fryer operates

cycle continuously.

 

 

normally, order replacement

 

 

controller from FASC.

 

 

A. Disconnect unit from electrical

 

A. Temporary controller malfunction

 

power, wait at least one minute,

CM III will not go

caused by voltage surge.

 

reconnect unit to the power

 

 

supply and turn controller on.

into programming

 

B.

If available, substitute controller

mode.

 

 

known to be good for suspect

 

B. Failed controller.

 

controller. If fryer operates

 

 

 

normally, order replacement

 

 

 

controller from FASC.

6-2

Page 37
Image 37
Frymaster 47 Series Burner will not, Solid state analog, controller power and, trouble lights on, but, mode