3.Open the drain valve slowly to avoid splattering. If the drain valve becomes clogged with food particles, use the steel clean-out rod to clear the blockage.

DANGER

NEVER attempt to clear a clogged drain valve from the front of the valve! Hot oil or shortening will rush out creating the potential for severe burns.

DO NOT hammer on the drain valve with the cleanout rod or other objects. Damage to the ball inside will result in leaks and will void the Frymaster warranty.

4.After draining the oil/shortening, clean all food particles and residual oil/shortening from the frypot. BE CAREFUL, this material may still cause severe burns if it comes in contact with bare skin.

5.Close the drain valve securely and fill the frypot with clean, filtered or fresh cooking oil or solid shortening to the bottom OIL-LEVELline.

DANGER

When using solid shortening, pack it down into the bottom of the frypot. DO NOT operate the fryer with a block of shortening sitting in the upper portion of the frypot. This will cause damage to the frypot and may cause a flash fire.

4.2Operation of the FootPrint III Built-In Filtration System

The FootPrint III (FP III) filtration system allows cooking oil or shortening in one frypot to be safely and efficiently filtered while the other frypots in a battery remain in operation. Operation of the FootPrint III system is illustrated in the steps below. Most reported problems with these systems are caused by improper operation. Careful attention to the instructions that follow will ensure that your system operates as intended.

4.2.1 Preparing the Filter Unit for Use and/or Changing the Filter Paper

1. Pull the filter unit from the cabinet, open the cover, and remove the crumb tray.

4-2

Page 25
Image 25
Frymaster 47 Series operation manual