PROBLEM

PROBABLE CAUSES

CORRECTIVE ACTION

 

A. Plugged openings or solidified

 

 

shortening in the Power Shower.

A. Clean the Power Shower per

 

Test: Look for oil/shortening

 

instructions in Chapter 5 of this

 

squirting out around the Power

manual.

 

Shower gasket. If so, Power

 

Power Shower is not

Shower is obstructed.

 

B. Missing/worn O-rings and gasket

B. Verify that O-rings and gasket are

spraying properly.

 

on Power Shower.

present and in good condition.

 

C. Missing paper in filter pan. (This

 

 

causes too much pressure in the

 

 

oil return lines, resulting in a

C. Verify that filter paper is properly

 

strong flow through the Power

installed in the filter pan.

 

Shower, but also squirting of oil

 

 

from around the gasket.)

 

6.6Replacing the Ignition Module Fuse in Units with Electronic Ignition

1.Disconnect the fryer from the electrical supply and remove the two screws in the upper corners of the control panel. Swing the panel open from the top, allowing it to rest on its hinge tabs.

2.Locate the 3-amp ignition module fuse (refer to illustration below) and, using a fuse-puller, remove and replace it with a new fuse.

Ignition Module

Depending upon when the unit was manufactured, full vat units may have either one or two ignition modules. If there is only one ignition module, the fuse will be mounted on the interface board.

Dual vat units and some full vat units will have two ignigiton modules. Look for the fuse on the left side of the module. If there are no fuses on the modules, the fuse will be on the interface board.

For units in which the ignition module has no fuse, replace the

upper fuse on the interface board.

3.Close the panel, replace the control panel screws, and reconnect the fryer to the electrical supply.

6-6

Page 41
Image 41
Frymaster 47 Series operation manual Power Shower is not, Spraying properly