Lightolier H9S1GLR132 Page 2 of, Ordering Information, Specifications continued, Job Information

Models: H9S1GLR232 H9S1GLR132

1 2
Download 2 pages 44.33 Kb
Page 2
Image 2
HP90 Recessed Fluorescent H9S1GLR132 or 232

HP90 Recessed Fluorescent H9S1GLR132 or 232

Page 2 of 2

Direct/Indirect – 1' x 4' with Acrylic Linear Prismatic Lens Static, 1 or 2 Lamp T8

Model No. H9S1GLR132UNVHI

LER = FP - 86.4 IW - 21.3 BF - 0.88 Comparative yearly lighting ene gy cost per

1000 lumens = $2.78

Report Number: G2007129

Catalog Number: H9S1GLR132UNVHI

Lamps: (1) F28 T8

Luminaire: HP90 1' x 4' with linear prismatic lens.

Ballast: QTP1X32T8-UNV-PSX-TC

Report is based on 2725 Lumens per lamp. Efficiency: 76.7%

CIE Type-Direct-Indirect

 

 

 

 

Plane:

 

 

 

 

0-Deg

 

90-Deg

Spacing Criteria:

 

 

1.2

 

 

1.4

Shielding Angles:

 

 

90

 

 

90

Plane:

 

 

 

 

0-Deg

 

90-Deg

Luminous Length:

 

47.040

 

11.040

COEFFICIENTS OF UTILIZATION –

 

 

ZONAL CAVITY METHOD. EFFECTIVE

 

FLOOR CAVITY REFLECTANCE 0.20

 

RC

 

80

 

 

50

 

 

30

 

RW

70

50

30

50

30

10

50

30

10

1

84

80

77

75

73

70

72

70

68

2

76

70

65

66

62

58

63

60

57

3

69

61

55

58

53

49

56

51

48

4

63

54

47

51

46

41

49

45

41

5

58

48

41

46

40

36

44

39

35

6

54

43

36

41

35

31

40

35

31

7

50

39

32

37

32

27

36

31

27

8

46

36

29

34

28

24

33

28

24

9

43

33

26

31

26

22

30

25

22

10

40

30

24

29

24

20

28

23

20

 

 

 

 

 

 

 

 

 

 

LUMINANCE DATA IN CANDELA/SQ. METER

AVERAGE AVERAGE AVERAGE AVERAGE IN DEG. 0-DEG. 45-DEG. 90-DEG.

45 1793. 2194. 2494.

55 1613. 2237. 2434.

65 1355. 2040. 1913.

75 1014. 1499. 1210.

85 616. 822. 753.

CANDELA DISTRIBUTION

 

0.0

45.0

90.0

FLUX

0

693

693

693

 

5

685

690

696

66

15

657

674

689

191

25

603

639

673

295

35

525

587

644

367

45

425

520

591

396

55

310

430

468

365

65

192

289

271

260

75

88

130

105

124

85

18

24

22

27

90

3

3

3

 

 

 

 

 

 

ZONAL LUMEN SUMMARY

ZONE

LUMENS

% LAMP

% FIXT

0- 30

551

20 2

26.4

0- 40

919

33 7

44.0

0- 60

1679

61 6

80.4

0- 90

2090

76 7

100.0

90-180

0

0 0

0.0

0-180

2090

76 7

100.0

Model No. H9S1GLR232UNVHI

LER = FP - 75.1 IW - 50.3 BF - 0.88 Comparative yearly lighting ene gy cost per

1000 lumens = $3.19

Report Number: G2007128

Catalog Number: H9S1GLR232UNVHI

Lamps: (2) F28T8

Luminaire: HP90 1' x 4' with linear prismatic lens.

Ballast: QTP2X32T8/UNV-ISN-SC

Report is based on 2725 Lumens per lamp. Efficiency: 78.8%

CIE Type-Direct-Indirect

 

 

 

 

Plane:

 

 

 

 

0-Deg

 

90-Deg

Spacing Criteria:

 

 

1.2

 

 

1.3

Shielding Angles:

 

 

90

 

 

90

Plane:

 

 

 

 

0-Deg

 

90-Deg

Luminous Length:

 

47.040

 

11.040

COEFFICIENTS OF UTILIZATION –

 

 

ZONAL CAVITY METHOD. EFFECTIVE

 

FLOOR CAVITY REFLECTANCE 0.20

 

RC

 

80

 

 

50

 

 

30

 

RW

70

50

30

50

30

10

50

30

10

1

86

82

79

77

75

72

74

72

70

2

78

72

67

68

63

60

65

62

59

3

71

63

57

59

54

50

57

53

49

4

65

56

49

53

47

43

51

46

42

5

60

50

43

47

41

37

46

41

37

6

55

45

38

43

37

32

41

36

32

7

51

41

34

39

33

29

38

32

28

8

48

37

30

35

30

25

34

29

25

9

45

34

28

33

27

23

32

27

23

10

42

31

25

30

25

21

29

24

21

 

 

 

 

 

 

 

 

 

 

LUMINANCE DATA IN CANDELA/SQ. METER

AVERAGE AVERAGE AVERAGE AVERAGE

IN DEG.

0-DEG. 45-DEG. 90-DEG.

45

3873.

4405.

4806.

55

3496.

4338.

4604.

65

2972.

3939.

3932.

75

2271.

3066.

2640.

85

1404.

1540.

1472.

CANDELA DISTRIBUTION

 

0.0

45.0

90.0

FLUX

0

1506

1506

1506

 

5

1488

1498

1509

143

15

1427

1450

1474

410

25

1308

1355

1399

625

35

1135

1216

1294

762

45

918

1044

1139

800

55

672

834

885

720

65

421

558

557

523

75

197

266

229

259

85

41

45

43

52

90

7

4

4

 

 

 

 

 

 

ZONAL LUMEN SUMMARY

ZONE

LUMENS

% LAMP

% FIXT

0- 30

1178

21 6

27.4

0- 40

1940

35 6

45 2

0- 60

3461

63 5

80 6

0- 90

4295

78 8

100 0

90-180

0

0 0

0 0

0-180

4295

78 8

100 0

Ordering Information

Explanation of Catalog Number. Example: H9S1GLR232UNVHI

S

1

G

L

R

32

 

 

 

 

 

 

 

 

 

Reflector:

Lamp

 

 

 

 

 

 

 

 

 

 

HP90

Body Style:

Fixture

Ceiling

 

Type:

Ac ylic Lens

 

 

 

 

 

 

 

 

 

 

 

 

Lamp:

Voltage:

 

 

Options:

Direct/Indi ect

S = Static

Width

Fits both

 

Specular

Quantity

 

(By Others)

120, 277 or

 

Add appropriate

Recessed

 

 

Standard Grid

 

Aluminum

1=1 Lamp

 

32=T8 32W *

UNV=120-277

 

suffix to catalog

 

 

 

 

and

 

 

2=2 Lamp

 

(Nominal 48")

 

 

 

no., ie: (GLR)

 

 

 

 

Slot Grid

 

 

 

* 28W T8 available

 

Ballast Type:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

<20THD <10THD

H9

 

Standard HP90

 

 

 

 

 

 

 

 

 

 

 

 

1 or 2 Lamp Elec. T8

SO *

 

HI *

 

 

 

 

 

 

 

 

 

 

 

 

 

LOL Dimming T8

PS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*Instant Start Standard

 

 

 

HY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

For NYC Code – I B.E.W. Manufactured

 

 

 

 

 

 

 

 

 

 

 

Other dimming options. Consult factory.

 

 

 

 

 

 

 

 

 

 

 

 

NOTE: For T8 UNV, you must use HI Ballast

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HN

 

For NYC Code – Local 3 Manufactu ed

 

 

 

 

 

 

 

 

 

 

 

Code.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Options/Accessories

 

 

 

 

 

 

Specifications (continued)

 

 

 

Fusing: Internal fast blow fusing: SUFFIX: GLR. Internal slow blow fusing: SUFFIX: GMF.

Drywall Kit: Order Catalog Number: FK91X4.

Electrical Wiring Options: Consult factory.For motion or light sensor: See Folio OA20-10.

Specifications

Electrical: Thermally protected class “P’ ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°.

UL Listed for damp locations. Labels: I.B.E.W./UL and ULc Listed.

This product may have a mercury containing lamp. Manage in accord with Disposal Laws. See: www.lamprecycle.org

Performance: In an installation of 2 lamp 28W luminaires in a room cavity ratio of 1, with reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .80. To reduce glare the average brightness at 65° shall not exceed 1913 candelas per square meter. To control veiling reflections, luminaire output in the 30°-90° zone shall not be less than 73.6%.

Materials: Chassis parts are die-formed code gauge steel.

Lamp Shield: Linear prismatic translucent DR acrylic lens.

Finish: Chassis exterior – baked white polyester enamel. Cavity – baked white polyester enamel. Rust preventative undercoating. Reflector – low irides- cence specular aluminum 95% reflectance.

 

Job Information

Type:

 

 

 

Lightolier a Genlyte company

www.lightolier.com

Technical Information: (978) 657-7600 • Fax (978) 658-0595

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish.

© 2007 a Genlyte company

Section 5/Folio M32-19

Page 2
Image 2
Lightolier Page 2 of, Ordering Information, Specifications continued, HP90 Recessed Fluorescent H9S1GLR132 or, Type