HP90 Recessed Fluorescent H9S2GLR254 or 154

Page 2 of 2

Direct/Indirect – 2' x 4' with Acrylic Linear Prismatic Lens

 

Static, 1 or 2 Lamp T5

Model No. H9S2GLR154UNVPG

LER = FP - 57.1 IW - 62.4 BF - 1.0 Comparative yearly lighting energy cost per

1000 lumens = $4.20

Report Number: G2006154

Catalog Number: H9S2GLR154UNVPG

Lamps: F54 T5 HO

Luminaire: HP90 2' x 4' with linear prismatic lens.

Ballast: Advance ICN-2S54 UNV PG Report is based on 4400 Lumens per lamp.

Efficiency: 81.0%

CIE Type-Direct-Indirect

 

 

 

 

Plane:

 

 

 

 

0-Deg

 

90-Deg

Spacing Criteria:

 

 

1.3

 

 

1.2

Shielding Angles:

 

 

90

 

 

90

Plane:

 

 

 

 

0-Deg

 

90-Deg

Luminous Length:

 

47.760

 

23.760

COEFFICIENTS OF UTILIZATION –

 

 

ZONAL CAVITY METHOD. EFFECTIVE

 

FLOOR CAVITY REFLECTANCE 0.200

 

RC

 

80

 

 

50

 

 

30

 

RW

70

50

30

50

30

10

50

30

10

01

89

85

82

80

77

75

77

75

73

02

81

74

69

70

66

62

67

64

61

03

74

66

59

62

57

53

60

55

52

04

68

58

51

55

50

45

53

49

45

05

63

52

45

50

44

39

48

43

39

06

58

47

40

45

39

35

44

38

34

07

54

43

36

41

35

31

40

35

31

08

50

39

33

38

32

28

37

31

27

09

47

36

30

35

29

25

34

29

25

10

44

33

27

32

27

23

31

26

23

LUMINANCE DATA IN CANDELA/SQ. METER

AVERAGE AVERAGE AVERAGE AVERAGE

IN DEG.

0-DEG. 45-DEG. 90-DEG.

45

1717.

1537.

1580.

55

1424.

1347.

1528.

65

1031.

1260.

1761.

75

638.

1271.

1672.

85

157.

157.

157.

CANDELA DISTRIBUTION0

 

 

 

0.0

45.0

90.0

FLUX

0

1393

1393

1393

 

5

1374

1395

1411

133

15

1323

1360

1366

382

25

1235

1232

1213

566

35

1101

1028

1017

651

45

889

796

818

631

55

598

566

642

529

65

319

390

545

410

75

121

241

317

239

85

10

10

10

24

90

2

2

2

 

 

 

 

 

 

ZONAL LUMEN SUMMARY

ZONE

LUMENS

% LAMP

% FIXT

00-030

1081

24.6

30.3

00-040

1732

39.4

48.6

00-060

2892

65.7

81.1

00-090

3566

81.0

100.0

90-180

0000

0.0

000.0

00-180

3566

81.0

100.0

Model No. H9S2GLR254UNVPG

LER = FP - 66.5 IW - 112.39 BF - 1.0 Comparative yearly lighting energy cost per

1000 lumens = $3.61

Report Number: G2006118

Catalog Number: H9S2GLR254UNVPG

Lamps: F54 T5 HO

Luminaire: HP90 2' x 4' with linear prismatic lens.

Ballast: B254UNV-E

Report is based on 4400 Lumens per lamp. Efficiency: 84.6%

CIE Type-Direct-Indirect

 

 

 

 

Plane:

 

 

 

 

0-Deg

 

90-Deg

Spacing Criteria:

 

 

1.3

 

 

1.4

Shielding Angles:

 

 

90

 

 

90

Plane:

 

 

 

 

0-Deg

 

90-Deg

Luminous Length:

 

46.800

 

22.800

COEFFICIENTS OF UTILIZATION –

 

 

ZONAL CAVITY METHOD. EFFECTIVE

 

FLOOR CAVITY REFLECTANCE 0.200

 

RC

 

80

 

 

50

 

 

30

 

RW

70

50

30

50

30

10

50

30

10

01

92

88

84

82

79

77

79

77

74

02

83

76

70

71

67

63

69

65

61

03

76

67

59

63

57

52

60

56

51

04

69

59

51

56

49

44

54

48

44

05

64

52

45

50

43

38

48

42

38

06

59

47

39

45

38

33

43

37

33

07

54

43

35

41

34

29

39

34

29

08

50

39

32

37

31

26

36

30

26

09

47

36

29

34

28

24

33

27

23

10

44

33

26

31

25

21

31

25

21

LUMINANCE DATA IN CANDELA/SQ. METER

AVERAGE AVERAGE AVERAGE AVERAGE

IN DEG.

0-DEG. 45-DEG. 90-DEG.

45

3179.

3676.

3752.

55

2970.

3405.

3615.

65

2649.

3309.

3776.

75

2149.

3507.

3731.

85

1250.

1583.

1000.

CANDELA DISTRIBUTION0

 

0.0

45.0

90.0

FLUX

0

2340

2340

2340

 

5

2320

2339

2354

223

15

2228

2326

2406

658

25

2079

2280

2417

1044

35

1851

2134

2220

1303

45

1548

1790

1827

1348

55

1173

1345

1428

1197

65

771

963

1099

950

75

383

625

665

597

85

75

95

60

125

90

0

0

0

 

 

 

 

 

 

ZONAL LUMEN SUMMARY

ZONE

LUMENS

% LAMP

% FIXT

00-030

1926

21.9

25.9

00-040

3229

36.7

43.4

00-060

5774

65.6

77.5

00-090

7446

84.6

100.0

90-180

0000

00.0

000.0

00-180

7446

84.6

100.0

Ordering Information

Explanation of Catalog Number. Example: H9S2GLR254UNVPGGLR

 

 

 

 

 

S

 

2

 

 

 

 

 

 

 

 

 

 

 

HP90

 

Body Style:

 

Fixture

Direct/Indirect

 

S = Static

 

Width

 

Recessed

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H9

Standard HP90

 

 

 

 

 

 

 

 

HY

 

For NYC Code – I.B.E.W. Manufactured

 

 

 

 

HN

For NYC Code – Local 3 Manufactured

G

 

L

Ceiling

 

Type:

 

 

 

Acrylic Lens

Fits both

 

 

Standard Grid

 

 

and

 

 

Slot Grid

 

 

R

Reflector:

Specular

Aluminum

 

 

 

54

 

 

 

 

Lamp

Lamp:

Quantity

(By Others)

1=1 Lamp

54=T5 54W

2=2 Lamp

(Nominal 48")

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Voltage:

 

 

 

Options:

120, 277 or

 

 

Add appropriate

UNV=120-277

 

 

suffix to catalog

 

 

 

 

 

 

 

no., ie: (GLR)

 

 

 

Ballast Type:

 

 

 

 

 

 

 

 

 

<20THD <10THD

1 Lamp Elec. T5 HO

 

 

PG ††

 

(54 Watt)

 

 

 

PG ††

2 Lamp Elec. T5 HO

 

 

 

(54 Watt)

 

 

 

 

 

 

††Program Rapid Start (UNV only)

Options/Accessories

Fusing: Internal fast blow fusing: SUFFIX: GLR.

Internal slow blow fusing: SUFFIX: GMF.

Drywall Kit: Order Catalog Number: FK92X4.

Electrical Wiring Options: Consult factory.

For motion or light sensor: See Folio OA20-10.

Specifications

Performance: In an installation of 2 lamp 54W luminaires in a room cavity ratio of 1, with reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .88. To reduce glare the average brightness at 65° shall not exceed 3776 candelas per square meter. To control veiling reflections, luminaire output in the 30°-90° zone shall not be less than 74.1%.

Materials: Chassis parts are die-formed code gauge steel.

Lamp Shield: Linear prismatic translucent DR acrylic lens.

Finish: Chassis exterior – baked white acrylic enamel. Cavity – baked flat white acrylic enamel. Phosphate undercoating. Reflector – low iridescence specular aluminum 95% reflectance.

Specifications (continued)

Electrical: Thermally protected class “P’ ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°.

UL Listed for damp locations. Labels: I.B.E.W./UL and ULc Listed.

This product may have a mercury containing lamp. Manage in accord with Disposal Laws. See: www.lamprecycle.org

Job Information

Type:

 

 

Lightolier a Genlyte company

www.lightolier.com

Technical Information: (978) 657-7600 • Fax (978) 658-0595

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710

We reserve the right to change details of design, materials and finish.

© 2006 a Genlyte company

Section 5/Folio M32-11

Page 2
Image 2
Lightolier HP90, H9S2GLR154, H9S2GLR254 dimensions Ordering Information, Options/Accessories, Specifications, Job Information

HP90, H9S2GLR254, H9S2GLR154 specifications

Lightolier is a well-established name in the world of lighting solutions, renowned for combining innovative technology with practical design to create energy-efficient lighting products. Among their standout offerings are the H9S2GLR154, H9S2GLR254, and HP90, each designed to cater to various lighting needs while ensuring aesthetic appeal and energy efficiency.

The H9S2GLR154 and H9S2GLR254 are versatile recessed lighting fixtures perfect for both residential and commercial applications. These units are equipped with advanced LED technology that ensures high lumen output with significant energy savings, making them an eco-friendly choice. The H9S2GLR series features innovative optical systems that provide uniform light distribution, eliminating harsh shadows and bright spots. With a sleek design, they blend seamlessly into any ceiling, offering a minimalist aesthetic that enhances the decor.

One of the key characteristics of the H9S2GLR154 and H9S2GLR254 is their adaptability. They support a variety of trims, allowing users to customize the look and feel. Furthermore, with dimmable options available, these fixtures provide flexibility in creating the desired ambiance. They are built to last, with durable materials and advanced thermal management systems that ensure longevity and reduce maintenance costs.

On the other hand, the HP90 is a high-performance high bay lighting solution tailored for industrial and commercial environments. This fixture utilizes state-of-the-art LED technology, offering an impressive lumen output that can illuminate large spaces effectively. The HP90 is designed with a rugged yet lightweight construction, making it easy to install and capable of withstanding the rigors of industrial settings.

The HP90 is also renowned for its energy efficiency, with a significant reduction in energy consumption compared to traditional high bay lighting options. This model incorporates features such as enhanced heat dissipation systems, which prolong the lifespan of the LEDs, and advanced optical designs for optimal light distribution. Additionally, the HP90 comes with various mounting options, providing versatility for different installation requirements.

In summary, the Lightolier H9S2GLR154, H9S2GLR254, and HP90 are prime examples of how modern lighting solutions can meet diverse needs. With their combination of energy efficiency, innovative technologies, and stylish designs, these lighting fixtures are ideal choices for anyone looking to enhance their space while also being kind to the environment. Whether for residential, commercial, or industrial use, Lightolier continues to set the standard in the lighting industry.