Lightolier H9S2GLR1FT Ordering Information, Options/Accessories, Specifications, Deg 90-Deg

Models: H9S2GLR1FT

1 2
Download 2 pages 41.88 Kb
Page 2
Image 2

HP90 Recessed Fluorescent H9S2GLR1FT

Page 2 of 2

Model No. H9S2GLR1FTUNVPR

LER = FP - 61.2 IW - 37.55 BF - 1.0 Comparative yearly lighting energy cost per

1000 lumens = $3.92

Report Number: G2006149

Catalog Number: H9S2GLR1FTUNVPR

Lamps: F40BX/SPX30/IS

Luminaire: HP90 2' x 2' with linear prismatic lens.

Ballast: C240PUNVHP-B/UNV

Report is based on 3150 Lumens per lamp. Efficiency: 72.9%

CIE Type-Direct-Indirect

 

 

 

 

Plane:

 

 

 

 

0-Deg

 

90-Deg

Spacing Criteria:

 

 

1.2

 

 

1.2

Shielding Angles:

 

 

90

 

 

90

Plane:

 

 

 

 

0-Deg

 

90-Deg

Luminous Length:

 

23.760

 

23.760

COEFFICIENTS OF UTILIZATION –

 

 

ZONAL CAVITY METHOD. EFFECTIVE

 

FLOOR CAVITY REFLECTANCE 0.200

 

RC

 

80

 

 

50

 

 

30

 

RW

70

50

30

50

30

10

50

30

10

01

80

76

73

71

69

67

69

67

65

02

73

67

62

63

59

56

60

57

54

03

66

59

53

55

51

47

53

49

46

04

61

52

46

49

44

40

48

43

40

05

56

47

40

44

39

35

43

38

40

06

52

42

36

40

35

31

39

34

30

07

48

38

32

37

31

27

36

31

27

08

45

35

29

34

28

24

33

28

24

09

42

32

26

31

26

22

30

25

22

10

39

30

24

29

24

20

28

23

20

LUMINANCE DATA IN CANDELA/SQ. METER

AVERAGE AVERAGE AVERAGE AVERAGE

IN DEG.

0-DEG. 45-DEG. 90-DEG.

45

2174.

2011.

2049.

55

1914.

1789.

1976.

65

1494.

1611.

2065.

75

1029.

1580.

2068.

85

598.

765.

598.

 

 

 

 

Direct/Indirect – 2' x 2' with Acrylic Linear Prismatic Lens

 

 

 

 

 

Static, 1 Lamp TT5

CANDELA DISTRIBUTION0

 

 

 

 

0.0

45.0

90.0

FLUX

 

0

876

876

876

 

 

5

868

872

876

83

 

15

836

841

845

238

 

25

776

776

772

357

 

35

685

665

646

416

 

45

560

518

528

410

 

55

400

373

413

348

 

65

230

248

318

260

 

75

97

149

195

155

 

85

19

24

19

31

 

90

2

2

2

 

 

 

 

 

 

 

 

ZONAL LUMEN SUMMARY

ZONE

LUMENS

% LAMP

% FIXT

00-030

678

21.5

29.5

00-040

1093

34.7

47.6

00-060

1851

58.8

80.6

00-090

2296

72.9

100.0

90-180

0000

0.0

000.0

00-180

2296

72.9

100.0

Ordering Information

Explanation of Catalog Number. Example: H9S2GLR1FTUNVPR

S

2

G

L

R

1

FT

 

 

 

 

 

 

 

 

 

 

Reflector:

Lamp

 

 

HP90

Body Style:

Fixture

Ceiling

 

Type:

Acrylic Lens

 

 

 

Lamp:

Direct/Indirect

S = Static

Width

Fits both

 

Specular

Quantity

(By Others)

Recessed

 

 

Standard Grid

 

Aluminum

1=1 Lamp

 

 

 

 

 

 

 

and

 

 

 

 

 

 

 

 

 

 

Slot Grid

 

 

 

 

 

H9

 

Standard HP90

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HY

 

 

For NYC Code – I.B.E.W. Manufactured

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HN

 

For NYC Code – Local 3 Manufactured

 

 

 

 

 

 

 

 

 

Options/Accessories

Fusing: Internal fast blow fusing: SUFFIX: GLR.

Internal slow blow fusing: SUFFIX: GMF.

Drywall Kit: Order Catalog Number: FK92X2.

Electrical Wiring Options: Consult factory.

For motion or light sensor: See Folio OA20-10.

Voltage:

 

 

 

 

 

 

 

 

 

Options:

120, 277 or

 

 

Add appropriate

UNV=120-277

 

 

suffix to catalog

 

 

 

 

 

no., ie: (GLR)

 

 

Ballast Type:

 

 

 

 

 

 

<20THD <10THD

1 Lamp Elec. TT5

 

 

SB*

IB**

(40 Watt)

 

 

PR†

1 Lamp Elec. TT5

 

 

(40 Watt)

 

 

BE*

 

 

1 Lamp Elec. TT5

 

 

 

(50 Watt)

 

 

BF*

1 Lamp Elec. TT5

 

 

(55 Watt)

 

 

PB

 

LOL Dimming TT5

 

 

 

*Instant Start Standard.

 

 

Other dimming options. Consult factory.

NOTE:

For TT5 40W UNV, you must use PR Ballast Code. †Program Rapid Start

Specifications

Performance: In an installation of 1 lamp 40W luminaires in a room cavity ratio of 1, with reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .96. To reduce glare the average brightness at 65° shall not exceed 2617 candelas per square meter. To control veiling reflections, luminaire output in the 30°-90° zone shall not be less than 69.5%.

Materials: Chassis parts are die-formed code gauge steel.

Lamp Shield: Linear prismatic translucent DR acrylic lens.

Finish: Chassis exterior – baked white acrylic enamel. Cavity – baked flat white acrylic enamel. Phosphate undercoating. Reflector – low iridescence specular aluminum 95% reflectance.

Electrical: Thermally protected class “P’ ballast C.B.M. approved, non PCB. If

K.O. is within 3" of ballast, use wire suitable for at least 90°. UL Listed for damp locations.

Labels: I.B.E.W./UL and ULc Listed.

This product may have a mercury containing lamp. Manage in accord with Disposal Laws. See: www.lamprecycle.org

Job Information

Type:

 

 

Lightolier a Genlyte company

www.lightolier.com

Technical Information: (978) 657-7600 • Fax (978) 658-0595

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710

We reserve the right to change details of design, materials and finish.

© 2006 a Genlyte company

Section 5/Folio M32-16

Page 2
Image 2