READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE INSTALLING FIXTURE | INSTRUCTION SHEET NO. | ||
This fixture is intended for installation in accordance with the National Electrical Code and local regulations. | IS:1104ICN | ||
To assure full compliance with local codes and regulations, check with your local electrical inspector before | |||
|
| ||
installation. To prevent electrical shock, turn off electricity at fuse box before proceeding. |
|
| |
Retain these instructions for maintenance reference. | C1204 | Page 2 of 2 | |
| |||
|
|
|
2. WIRE-IN (Fig. B)
Open hinged
Open hinged KNOCK OUT to allow
Note: Wiring and connections must not be placed in JUNCTION BOX in a manner which will interfere with the CLAMPS action to provide strain relief.
Wire to SUPPLY LEADS. WHITE FIXTURE LEAD to NEUTRAL SUPPLY | HINGED KNOCK OUT |
LEAD. BLACK FIXTURE LEAD to HOT (120V) SUPPLY LEAD. BARE FIX- |
|
TURE WIRE to SUPPLY GROUND. Use wirenuts (local hardware item). |
|
Place all electrical connections in the |
|
COVER. |
|
SHEATHED CABLE |
|
(12 OR 14 GAUGE ONLY) |
|
CABLE CLAMP
3. SWING-UP (Fig. C)
JUNCTION BOX
Extend MOUNTING BAR to reach opposite joist and fasten in place. Adjust to desired position along MOUNTING BAR and lock in place.
4.CLOSE-IN (Fig. D)
Install plasterboard or other dry type ceiling. Hole in board
can be cut either on the floor or after the board is secured to the ceiling using HOUSING opening as cutting guide. HOUSING is secured by 3 screws which allow adjustment for variable ceiling thicknesses.
5.AIRSEAL® INSTALLATION (optional)
Option 1: Install LAS56 Flange Gasket Kit (available separately).
Option 2: Install a bead of silicone caulking compound between the ceiling opening and edge of HOUSING. Housings are tested in accordance with ASTM E 283 (max 2 cfm @ 75 pa) and comply with WSEC & MEC when installed as instructed.
NOTE: If factory installed tape or knockouts are removed from vertical adjustment slots in housing wall install LAS56 Flange Gasket Kit (available separately).
6.SNAP-ON (Fig. E)
Important - Insert SOCKET CUP in neck
of REFLECTOR making sure SPRING TABS fully engage into SLOTS in REFLECTOR. }SEE SEPARATEINSTRUCTIONREFLECTOR TRIM7.
Push REFLECTOR TRIM straight up until | SHEETS |
it is tight against ceiling. |
|
•Turn off power to fixture
•Remove lamp
•Squeeze REFLECTOR SPRING from inside until the TRIM disengages.
•To retrieve SOCKET CUP, pull on one of the SOCKET SPRING LEGS to disengage.
SQUEEZE CLIP Squeeze to adjust, release to lock
MOUNTING BAR
DEFORM MATERIAL HERE
FOR ADDITIONAL LOCK
SOCKET CUP
REFLECTOR SPRING
U.S. AND FOREIGN PATENTS PENDING
® |
LIGHTOLIER a GENLYTE company.
631 Airport Road, Fall River, MA 02720