5

INSTALLATION

Step 1 — Thermostat Location

SApproximately5 ft (1.5m) from floor.
SClose to or in a frequently used room, prefe rably on an inside partition-
ing wall.
SOna section of wall without pipes or duct work.
Thermostatshould NOT be mounted
SCloseto a window, on an outsidewall, or next to a door leading to the
outside.
SExposedto direct light or heat from the sun, a lamp, fireplace, or other
temperature--radiatingobjects which could cause a false reading.
SCloseto or in direct airflow fromsupply registers and return--airre-
gisters.
SInareas with poor air circulation,such as behind a door or in an alcove.

Step 2 — InstallThermostat

ELECTRICAL OPERATIONH AZARD
Failure to follow this warning couldresult in personal injury or
death.
Before installing thermostat, turn off all power to eq uipment. There
maybe more than one power disconnect.
!WARNING
1. Turn OFF all powerto unit.
2. If an existing thermostat isbeing replaced:
a. Remov e existing thermostat from wa ll.