READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE INSTALLING FIXTURE
This fixture is intended for installation in accordance with the National Electrical Code and local regulations. To assure full compliance with local codes and regulations, check with your local electrical inspector before installation. To prevent electric shock, turn off electricity at fuse box before proceeding.
Retain these instructions for maintenance reference.
INSTRUCTION SHEET NO.
IS:4X4
B0502 | Page 1 of 2 |
INSTALLATION PROCEDURE FOR: 4X4, 4X9, AND 9X9
MATRIX SERIES RECESSED DOWNLIGHTS.
CAUTION: (RISK OF FIRE) DO NOT INSTALL INSULATION ABOVE NOR WITHIN 3 INCHES (76mm) OF ANY
PART OF THE LUMINAIRE (FIXTURE)
CAUTION: USE ONLY REFLECTOR TRIMS PROVIDED BY LIGHTOLIER. USE OF OTHER MANUFACTURERS’ REFLECTOR
TRIMS MAY VOID THE UNDERWRITERS LABRATORIES LISTING AND COULD CONSTITUTE A FIRE HAZARD.
A. FRAME-IN AND WIRE-IN
Install
MOUNTING
BAR
ADJUSTABLE | ADJUSTMENT |
SCREW | |
MOUNTING | FIK. |
BRACKET | HOUSING |
FIG. 1
3/4” OR
CHANNEL (BY OTHERS)
ADJUSTABLE
MOUNTING
BRACKET
ADJUSTMENT SCREW
FIK.
HOUSING
FIG. 2
1/2” EMT
(11/16” OD) (BY OTHERS)
ADJUSTMENT
ADJUSTABLE | SCREW | |
MOUNTING | ||
FIK. | ||
BRACKET | HOUSING |
FIG. 3
For suspended
FIK must be securely attached to and unable to lift from ceiling members after installation is complete.
WIRE
ANCHOR CLIP
MOUNTING BAR
FIG. 4 | FIG. 5 |
For wood joist construction: Mounting bars may be used to secure FIK. to joists (Fig. 6). MOUNTING BARS may be bent where required90° to allow precise placement
of FIK between joists. Use nails to secure to joists.
MOUNTING BAR ordering information:
18” long: Cat. No. 1950
27” long: Cat. No. 1951
BALLAST |
|
| NAILS | JOISTS | |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
FIG. 6
MOUNTING BAR |
Note: If FIK is to be used with a
FIG. 7
Direction of wall to be washed