Lighting Systems LFK2
1BHFPG |
4.295"
(10.91cm)
4.895” (12.43cm)
1 2
3.400"
(8.64cm)
6 | 5 | 4 | 3 |
Ordering Information
Half Scale
Family |
|
| Lamps | |
LFK |
|
| 1 |
|
|
|
| ||
|
|
|
|
|
|
|
| 1 = 1 lamp per | |
|
|
| 4’ (121.92cm) | |
|
|
|
Complete Ordering Instructions below.
Shielding
L
L= Louver
|
| Wattage | Voltage | ||
|
|
|
|
| |
|
|
|
|
|
|
| 28 = 28w T5 |
| 1 = 120v | ||
| 54 = 54w T5 |
| 2 = 277v | ||
| 2D = 28w T5 Dimming |
| |||
| 5D = 54w T5 Dimming |
| |||
| 2E | = 28w T5 Emergency Pack | |||
| 5E | = 54w T5 Emergency Pack |
|
| Length | Options | |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 4 | = 4’ (121.92cm) |
| DS = Dual Switch | ||
| 8 | = 8’ (243.84cm) |
| X4 = 4 Through Wires | ||
|
|
|
|
| X5 = 5 Through Wires | |
|
|
|
|
|
|
|
Features
1.Extrusion: Extruded aluminum, painted white.
2.Housing:
3.Endcap: Die cast aluminum, painted white.
4.Ballast Channel: Accepts linear fluorescent ballasts up to 1.2" (3.05cm) wide by 1.2" (3.05cm) tall.
5.Lamp: T5 linear fluorescent, 28 or 54 watt. (by others).
Electrical
Ballast: Electronic and meets A.N.S.I. starting, end of life protection, T.H.D., "A" sound rating, and
Wiring: 3 Conductor 18 gauge wire.
Dimming: Advance Mark X. Use Advance compatible 2 wire control (no extra lead is required in the luminaire).
Emergency Battery Pack: 54 Watt:
Dual Switching: Order the DS option for separate row switching. DS option comes complete with the 4th through wire option.
4 and 5 wire: Order X4 for EM Battery Pack. For
Consult Factory for any additional wiring conditions.
Finish
Powder coated white baked enamel. Custom colors available, consult factory.
Mounting
Mounting locations are adjustable along the top of the extrusion. Cable suspension (not shown) consists of 4 1/2" (11.43cm) diameter canopy finished white enamel, 1/16" (0.16cm) diameter stainless steel aircraft cable adjustable up to 36”
(91.44cm).
Ordering Instructions
Individual Fixtures:
1.Order number of MODULES required.
2.Order one POWER FEED CABLE END SET per MODULE.
Continuous Rows:
1.Determine run length.
2.Order the appropriate number of MODULES for the complete run.
3.Order one POWER FEED CABLE END SET per run.
4.Order one INTERMEDIATE CABLE SET per MODULE minus one per run.
5.For runs that exceed amperage limits, order the appropriate number of
CABLE/CORD SET.
Labels
UL , cUL and I.B.E.W. Patent Applied For.
Job Information | Type: |
Job Name:
Cat. No.:
Lamp(s):
Notes:
"JSQPSU3PBE'BMM3JWFS."t t'BY
We reserve the right to change details of design, materials and finish.
XXXMJHIUPMJFSDPN½1IJMJQT(SPVQt #