Lighting Systems LFK2
1BHFPG |
Performance
CANDLEPOWER CURVE |
| CANDLEPOWER |
| |||
| ZONE | 0 | 22 | 45 | 67 | 90 |
| DEG. |
| CANDELAS |
|
| |
|
|
|
|
| ||
| 180 | 183 | 183 | 183 | 183 | 183 |
| 175 | 183 | 184 | 184 | 186 | 186 |
| 165 | 184 | 184 | 162 | 155 | 152 |
| 155 | 180 | 162 | 166 | 178 | 184 |
| 145 | 170 | 153 | 200 | 334 | 392 |
| 135 | 156 | 160 | 350 | 475 | 452 |
| 125 | 135 | 186 | 342 | 236 | 211 |
| 115 | 100 | 237 | 141 | 182 | 199 |
| 105 | 60 | 66 | 115 | 170 | 192 |
| 95 | 16 | 38 | 90 | 155 | 187 |
| 90 | 0 | 28 | 80 | 148 | 180 |
| 85 | 11 | 40 | 90 | 157 | 184 |
| 75 | 57 | 104 | 150 | 196 | 196 |
| 65 | 113 | 263 | 234 | 286 | 304 |
| 55 | 183 | 322 | 495 | 412 | 412 |
| 45 | 349 | 466 | 657 | 762 | 763 |
| 35 | 513 | 618 | 733 | 871 | 949 |
REPORT NO.: ITL54308 | 25 | 667 | 748 | 832 | 913 | 961 |
LAMPS: | 15 | 798 | 841 | 909 | 952 | 975 |
LUMENS: 5000 | 5 | 896 | 905 | 920 | 928 | 933 |
EFFICIENCY: 73.5% | 0 | 912 | 912 | 912 | 912 | 912 |
CAT NO.: LFK1L5414
Fixture Lengths & Mounting
8' (243.48cm) |
| 4' (121.92cm) |
|
|
|
|
|
|
|
|
| 8' (243.48cm) |
12’ | 8’ |
8' (243.48cm) | 8' (243.48cm) | 4' (121.92cm) |
| 16’ | 4’ |
|
| (123.83cm) |
8' (243.48cm) 8' (243.48cm) 4' (121.92cm)
20’
8' (243.48cm) 8' (243.48cm) 8' (243.48cm)
24’
Mounting Accessories
COEFFICIENTS OF UTILIZATION
% EFFECTIVE CEILING CAVITY REFLECTANCE
|
|
|
| 80% |
|
|
| 70% |
|
|
| 50% |
|
|
|
|
|
|
| WALL REFLECTANCE |
|
|
| ||||
|
|
| 70 | 50 | 30 |
| 70 | 50 | 30 |
| 50 | 30 | 10 |
| 0 | 82 | 82 | 82 |
| 77 | 77 | 77 |
| 69 | 69 | 69 | |
RATIO | 1 | 74 | 71 | 68 |
| 70 | 67 | 64 |
| 60 | 58 | 56 | |
3 | 62 | 55 | 49 |
| 58 | 52 | 47 |
| 46 | 42 | 39 | ||
| 2 | 68 | 62 | 57 |
| 64 | 59 | 55 |
| 52 | 49 | 46 | |
CAVITY | 4 | 57 | 49 | 43 |
| 53 | 46 | 41 |
| 41 | 37 | 34 | |
6 | 48 | 39 | 33 |
| 45 | 37 | 32 |
| 34 | 29 | 25 | ||
| 5 | 52 | 43 | 37 |
| 49 | 41 | 36 |
| 37 | 33 | 29 | |
ROOM | 7 | 45 | 35 | 29 |
| 42 | 34 | 28 |
| 31 | 26 | 23 | |
8 | 42 | 32 | 26 |
| 39 | 31 | 25 |
| 28 | 23 | 20 | ||
| 9 | 39 | 29 | 24 |
| 37 | 28 | 23 |
| 26 | 21 | 18 | |
| 10 | 36 | 27 | 22 |
| 34 | 26 | 21 |
| 24 | 19 | 16 |
20% FLOOR CAVITY REFLECTANCE
DISTRIBUTION |
|
| |
Zone | Lumens | % Lamp | %Luminaire |
2506 | 50.0 | 68.0 | |
1170 | 23.5 | 32.0 | |
3677 | 73.5 | 100.0 |
Note: All suspension points have 6" (15.24cm) of adjustment within each module. 12" (30.48cm) when two modules are joined. Field cutting of wire cover is required.
Power Feed Cable End Set
Cable length is 36" (91.44cm)
Straight Cord: LFKEC36WH
4 Wire Cord: LFKEC36WHX4
5 Wire Cord: LFKEC36WHX5
Intermediate Cable Set Cable length is 36" (91.44cm) Single Cable: LFKC36
Intermediate
Cable/Cord Set
Cable length is 36" (91.44cm)
Straight Cord: LFKCC36
4 Wire Cord: LFKCC36X4
5 Wire Cord: LFKCC36X5
Ceiling Grid Kit (CGK)
Includes both standard 1" (2.54cm) Tee and Slot Tee Clip.
Order one for every non- powered suspension point.
Ceiling Grid Kit—
Power (CGKP)
Includes the hardware necessary to install a power feed above a suspended ceiling.
Job Information | Type: |
"JSQPSU3PBE'BMM3JWFS."t t'BY
We reserve the right to change details of design, materials and finish.
XXXMJHIUPMJFSDPN½1IJMJQT(SPVQt #