Lytecel Linear LL4MF8LX232
Page 2 of 2
Model No. LL4MF8LX232120SO (8 Cell)
Uplight/Downlight, Pendant,
Model No. LL4MF12LX232120SO (12 Cell)
LER = FP - 70.9 IW - 58 | BF - 0.87 |
Comparative yearly lighting energy cost per 1000 lumens = $3.38
Report Number: G2004161
Catalog Number: LL4MF8LX232120SO
Lamp: FP32/T8 TL841
Luminaire: LL4 with no reflector, 8 cell louver
Ballast: Triad
Report is based on 2850 Lumens per lamp. Efficiency: 82.7%
CIE |
|
|
|
| |||||
Plane: |
|
|
|
|
| ||||
Spacing Criteria: |
|
| 1.2 |
|
| 1.9 | |||
Shielding Angles: |
|
| 65 |
|
| 55 | |||
Plane: |
|
|
|
|
| ||||
Luminous Length: |
| 48.000 |
| 6.480 | |||||
COEFFICIENTS OF UTILIZATION – |
|
| |||||||
ZONAL CAVITY METHOD. EFFECTIVE |
| ||||||||
FLOOR CAVITY REFLECTANCE 0.200 |
| ||||||||
RC |
| 80 |
|
| 50 |
|
| 30 |
|
RW | 70 | 50 | 30 | 50 | 30 | 10 | 50 | 30 | 10 |
01 | 80 | 77 | 74 | 68 | 57 | 55 | 47 | 46 | 45 |
02 | 74 | 68 | 63 | 52 | 49 | 47 | 42 | 40 | 39 |
03 | 67 | 60 | 55 | 46 | 43 | 40 | 38 | 35 | 33 |
04 | 62 | 53 | 47 | 41 | 37 | 34 | 34 | 31 | 29 |
05 | 57 | 48 | 41 | 37 | 33 | 30 | 30 | 27 | 25 |
06 | 52 | 43 | 36 | 33 | 29 | 26 | 27 | 24 | 22 |
07 | 48 | 38 | 32 | 30 | 26 | 23 | 25 | 22 | 19 |
08 | 45 | 35 | 29 | 27 | 23 | 20 | 23 | 19 | 17 |
09 | 41 | 32 | 26 | 25 | 21 | 18 | 21 | 18 | 15 |
10 | 39 | 29 | 23 | 23 | 19 | 16 | 19 | 16 | 14 |
LUMINANCE DATA IN CANDELA/SQ. METER
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. | |||
45 | 2362. | 3740. | 3424. |
55 | 1581. | 2214. | 1414. |
65 | 0320. | 0403. | 0228. |
75 | 0182. | 0097. | 0056. |
85 | 0133. | 0059. | 0024. |
CANDELA DISTRIBUTION0 |
|
| ||
| 0.0 | 45.0 | 90.0 | FLUX |
0 | 672 | 672 | 672 |
|
5 | 662 | 671 | 678 | 64 |
15 | 624 | 672 | 736 | 193 |
25 | 560 | 719 | 903 | 337 |
35 | 478 | 802 | 1068 | 493 |
45 | 369 | 754 | 846 | 515 |
55 | 208 | 408 | 335 | 307 |
65 | 33 | 65 | 50 | 66 |
75 | 13 | 13 | 011 | 15 |
85 | 5 | 6 | 4 | 6 |
90 | 3 | 4 | 4 |
|
|
|
|
|
|
ZONAL LUMEN SUMMARY
ZONE | LUMENS | % LAMP | % FIXT |
0594 | 10.4 | 012.6 | |
1087 | 19.1 | 023.1 | |
1909 | 33.5 | 040.5 | |
1997 | 35.0 | 042.4 | |
0695 | 12.2 | 014.7 | |
1212 | 21.3 | 025.7 | |
2130 | 37.4 | 045.2 | |
2718 | 47.7 | 057.6 | |
4715 | 82.7 | 100.0 |
LER = FP - 67.5 IW - 58 BF - 0.87 Comparative yearly lighting energy cost per
1000 lumens = $3.56
Report Number: G2004164
Catalog Number: LL4MF12LX232120SO
Lamp: F32/T8 TL841
Luminaire: LL4 with no reflector, 12 cell louver
Ballast: Triad
Report is based on 2850 Lumens per lamp. Efficiency: 79.2%
CIE |
|
|
|
| |||||
Plane: |
|
|
|
|
| ||||
Spacing Criteria: |
|
| 1.1 |
|
| 1.9 | |||
Shielding Angles: |
|
| 65 |
|
| 55 | |||
Plane: |
|
|
|
|
| ||||
Lumen Length: |
|
| 48.000 |
| 6.480 | ||||
COEFFICIENTS OF UTILIZATION – |
|
| |||||||
ZONAL CAVITY METHOD. EFFECTIVE |
| ||||||||
FLOOR CAVITY REFLECTANCE 0.200 |
| ||||||||
RC |
| 80 |
|
| 50 |
|
| 30 |
|
RW | 70 | 50 | 30 | 50 | 30 | 10 | 50 | 30 | 10 |
01 | 76 | 73 | 71 | 55 | 53 | 52 | 44 | 43 | 42 |
02 | 70 | 65 | 60 | 49 | 46 | 44 | 39 | 38 | 36 |
03 | 64 | 57 | 52 | 44 | 40 | 38 | 35 | 33 | 31 |
04 | 59 | 51 | 45 | 39 | 35 | 33 | 32 | 29 | 27 |
05 | 54 | 46 | 40 | 35 | 31 | 28 | 29 | 26 | 24 |
06 | 50 | 41 | 35 | 32 | 28 | 25 | 26 | 23 | 21 |
07 | 46 | 37 | 31 | 29 | 25 | 22 | 24 | 21 | 18 |
08 | 43 | 33 | 28 | 26 | 22 | 19 | 21 | 19 | 16 |
09 | 40 | 30 | 25 | 24 | 20 | 17 | 20 | 17 | 15 |
10 | 37 | 28 | 22 | 22 | 18 | 15 | 18 | 15 | 13 |
LUMINANCE DATA IN CANDELA/SQ. METER
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. | |||
45 | 2037. | 3417. | 3456. |
55 | 0631. | 1487. | 1228. |
65 | 0243. | 0205. | 0146. |
75 | 0140. | 0090. | 0046. |
85 | 0133. | 0049. | 0024. |
CANDELA DISTRIBUTION0 |
|
| ||
| 0.0 | 45.0 | 90.0 | FLUX |
0 | 651 | 651 | 651 |
|
5 | 640 | 649 | 656 | 62 |
15 | 596 | 644 | 704 | 185 |
25 | 523 | 685 | 905 | 326 |
35 | 434 | 778 | 1074 | 477 |
45 | 318 | 689 | 854 | 478 |
55 | 83 | 274 | 291 | 212 |
65 | 25 | 33 | 32 | 37 |
75 | 10 | 12 | 9 | 12 |
85 | 5 | 5 | 4 | 6 |
90 | 4 | 4 | 4 |
|
|
|
|
|
|
ZONAL LUMEN SUMMARY
ZONE | LUMENS | % LAMP | % FIXT |
0572 | 10.0 | 012.7 | |
1049 | 18.4 | 023.2 | |
1740 | 30.5 | 038.5 | |
1795 | 31.5 | 039.8 | |
0695 | 12.2 | 015.4 | |
1212 | 21.3 | 026.8 | |
2130 | 37.4 | 047.2 | |
2718 | 47.7 | 060.2 | |
4513 | 79.2 | 100.0 |
Ordering Information
Explanation of Catalog Number. Example: LL4MF8LX232120SOGLR
LL
X
*For any additional ballast or wiring combination consult factory. *8' units have lamps in tandem.
32
Lytecel | Fixture |
|
| Body | Number |
Linear: | Length: |
|
| Finish: | of Cells: |
Pendant |
| F | =White | 8= 1 row of 8 | |
4 = Nominal 48" |
| ||||
with 3” |
| B | =Black | 12= 1 row of 12 | |
8 = Nominal 96" |
| ||||
Deep Parabolic |
|
|
| (48” Length) | |
Precision |
| Body Style: |
|
| Louver Finish: |
Contoured |
|
|
| ||
| M = Individual |
|
| L = Low Iridescence | |
|
|
| |||
| Module |
|
| ||
Aluminum Louver |
|
| |||
J = Joiner |
|
| (standard) | ||
|
|
|
| ||
|
| Module |
|
| P = Low Iridescence |
|
|
|
|
| Specular |
W=White
Options/accessories
Stem Sets: 1/2” diameter tubing, 18” long, chrome plated finish. Catalog
Number: 18048.
Stem Extension Kit: 1/2" diameter tubing, 18” long, chrome plated finish
extension. Catalog Number: 18148.
Single Cable and Canopy. Catalog Number: WC60.Single Cable, Straight Cord and Canopy. Catalog Number: WCC60.
Single Cable, Coiled Cord and Canopy. Catalog Number: WCCC60.
Electrical Wiring Options: Consult factory.Fusing: Internal
Internal
Top | Lamp | Lamp Type/ | Voltage: |
|
| Options: |
Reflector: | Quantity* | Fixture Length: | 120 or 277 |
| Add appropriate | |
X=None | 1=1 Lamp | 32=T80 | UNV = Universal |
| suffix to catalog | |
| 2=2 Lamp | (Nominal 48") | Voltage |
| no, ie: (GLR) | |
| 3=3 Lamp |
|
|
| ||
|
|
|
| <20THD | <10THD | |
|
|
| 1 or 2 Lamp Elec. T8 | SO* | HI* | |
|
|
| ||||
|
|
| O3* | H3* | ||
|
|
| O4* | H4* | ||
|
|
| O6* | H6* | ||
|
|
| LOL Dimming T8 | PS | – | |
Specifications (continued) | *Instant Start Standard | |||||
|
|
|
Louver:
Finish:
Electrical: Thermally protected class “P” ballast, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°.
Labels: I.B.E.W./UL and ULc Listed.
Specifications
Performance: In an installation of 2 lamp 32W Iuminaires with a room cavity ratio of 1, with reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall be not less than .77. Candelas at 65° shall not exceed 66 (8 cell). To control veiling reflections, Iuminaire output in the 30°- 90° zone shall be not less than 87.4%.
Materials: Chassis parts are
Job Information | Type: |
|
|
Lightolier a Genlyte company | www.lightolier.com |
Technical Information: (978)
631 Airport Road, Fall River, MA 02720 • (508)
© 2005 a Genlyte company A0902