Performance - 54W T5

CANDLEPOWER CURVE

REPORT NO: ITL49764

CAT NO: LSC24C54

LAMPS: 2 F54T5

LUMENS: 5000

EFFICIENCY: 90.3%

-ZUFTQSFBEÜ-4$1JFSDFE-VNJOPVT*OEJSFDU-JHIU5QFS'PPU /PNJOBM 4FDUJPO

 

 

CANDLEPOWER

 

 

 

 

COEFFICIENTS OF UTILIZATION

 

 

ZONE

0

22

45

67

90

% EFFECTIVE CEILING CAVITY REFLECTANCE

DEG.

 

CANDELAS

 

 

 

 

80

 

 

70

 

 

 

50

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

180

1762

1762

1762

1762

1762

 

 

 

WALL REFLECTANCE

 

 

 

 

175

1760

1772

1774

1770

1772

 

70

50

30

70

50

30

 

50

30

10

165

1709

1754

1781

1791

1798

 

 

 

 

 

 

 

 

 

 

 

 

0

87

87

87

76

76

76

 

54

54

54

155

1599

1676

1714

1763

1786

1

79

76

72

69

66

63

 

47

45

43

145

1429

1527

1625

1754

1816

2

72

66

61

62

57

53

 

41

38

36

135

1213

1330

1546

1766

1870

3

66

58

52

57

50

45

 

36

32

30

125

959

1107

1473

1949

2175

4

60

51

44

52

44

39

 

32

28

25

115

668

895

1625

2290

2462

5

55

45

38

47

39

33

 

28

24

21

105

360

794

1557

1744

1738

6

50

40

33

43

35

29

 

25

21

18

95

71

449

397

408

394

7

46

36

29

40

31

26

 

22

19

16

90

0

16

30

43

61

8

43

32

26

37

28

23

 

20

17

14

85

9

28

36

61

69

9

40

29

23

34

26

20

 

18

15

12

75

22

34

57

82

89

10

37

27

21

32

23

18

 

17

13

11

65

47

60

78

100

107

 

 

20% FLOOR CAVITY REFLECTANCE

 

 

55

84

94

105

124

127

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

45

116

127

133

147

148

DISTRIBUTION

 

 

 

 

 

 

 

 

35

145

154

159

167

165

 

 

 

 

 

 

 

 

25

169

175

181

184

182

Zone

Lumens

 

% Lamp

% Luminaire

15

186

188

192

195

193

0-90

 

637

 

6.4

 

 

 

7.1

 

 

5

195

195

194

193

190

90-180

8390

 

83.9

 

 

 

92.9

 

 

0

194

194

194

194

194

0-180

9027

 

90.3

 

 

 

100.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Calculations are for 54 watt T5 lamps, for 28 watt T5 lamps divide by 1.7.

Fixture Lengths & Mounting Locations

48"

(121.92cm)

4-Foot

1BHFPG 4' 10" Performance - 54W T5CANDLEPOWER CURVE (147.32cm)

96" (243.84cm)

8-Foot

8' 10" (269.24cm) CANDLEPOWERDISTRIBUTION

144" (365.76cm)

4-Foot Run

8-Foot Run

12-Foot Run

16-Foot Run

20'-Foot Run

24'-Foot Run

4-Foot

8-Foot

12-Foot

Module

Module

Module

1

 

 

 

1

 

 

 

1

 

2

 

 

1

1

 

 

2

Power Feed

End Set

1

1

1

1

1

1

Cable/

Assembly

1

1

1

12-Foot

12' 10" (391.16cm)

96" (243.84cm) Fixture Lengths & Mounting LocationsMounting AccessoriesManual background 96" (243.84cm)

16-Foot

16' 10" (513.08cm)

5IFTFBSFUZQJDBMSVODPOmHVSBUJPOT3VOTDBOCFDPOTUSVDUFE VTJOHNBOZDPNCJOBUJPOTPGmYUVSFT

Manual background 144" (365.76cm) Manual backgroundManual background 96" (243.84cm)

20-Foot

20' 10" (635.00cm)

Manual background 144" (365.76cm) Manual backgroundManual background 144" (365.76cm) Manual backgroundManual background

24-Foot

24' 10" (756.92cm)

Mounting Accessories

Cable Assembly

Cable/Cord Assembly

Power Feed End Set

Single Cable: LSCC36

Single Cable & Cord: LSCCC36

Straight Cord: LSCEC36WH (white)

 

Single Cable & 4 Wire Cord*:

LSCEC36AL (aluminum)

 

LSCCC36X4

4 Wire Cord*: LSCEC36WHX4 (white)

LSCEC36ALX4 (aluminum)

* Use for dimming and/or emergency battery packs

Ceiling Grid Kit

CGK

Includes both Standard 1” (2.54 Tee Bar Clip & Slot Tee Clip. Order 1 Kit per mounting point.