Lightolier MD2G2SB Page 4 of, Ordering Information, Options/Accessories, Specifications, Type

Models: MD2G2SB

1 4
Download 4 pages 9.42 Kb
Page 4
Image 4
Page 4 of 4

MD*4TM 2' x 2' Recessed or Surface MD2G2SB

Page 4 of 4

Multi-Function Patient Lighting

ORDERING INFORMATION

Explanation of Catalog Number. Example: MD2G2SB120SW

MD

 

2

 

G

 

 

 

 

 

 

 

2

 

 

 

 

 

 

MD*4

 

Fixture

 

Ceiling

Recessed or

 

Size:

 

Type:

Surface,

 

2' x 2'

 

Same Unit

Multi-function

 

 

 

 

May Be Used

 

 

 

 

Patient Light

 

 

 

 

For: Grid (lay-in)

 

 

 

 

 

T-bar or

 

 

 

 

 

 

 

 

 

 

Surface

 

 

 

 

 

Mounted

 

 

 

 

 

 

Lamp

 

 

 

Quantity:

 

 

 

(Ambient/

 

 

 

Reading)

 

 

 

2 Lamps

 

 

 

(Total)

Ballast Type:

 

 

 

 

(Ambient Reading)

 

 

 

<20THD

<10THD

 

1-2 Lamp Elec. TT5

SB*

IB*

 

(40 Watt)

 

PR**

 

1-2 Lamp Elec. TT5

 

LOL Dimming TT5

PB

*Instant Start Standard **Program Start

NOTE:

For TT5 UNV, you must use IB Ballast

Code

 

 

 

 

Voltage:

Options:

120, 277 or

Add appropriate

UNV=120-277

Suffix to Catalog

 

 

No. i.e. (GLR)

 

 

 

 

Options/Accessories

Access Plates: Top wiring access plate is shipped with fixture as standard. When access plates are required in advance for wiring convenience, specify separately. Catalog Number: ACP.

Drywall Kit or Plaster Ceiling: Order Catalog Number: FK92X2. Request Folio OA30-10.

For Chicago Plenum add Suffix: CP.

Electronic Sequential Switch (Low Voltage): Switch factory mounted in fixture for ambient and reading light convenience (controlled by pillow switch, by others). Suffix: SW.

Nurses Night Light: 120 volt medium base, narrow spot, 50W reflector lamp with specular anodized mirror, field adjustable to right or left side of patient's bed. Suffix: NL.

Night Light: 120 volt, 3 watt, cool white LED (50,000 hours life). Suffix: LD.

Fusing: Internal fast-blow fusing. Suffix: GLR. Internal slow-blow fusing. Suffix: GMF.

Radio Interference Filter: To order one RIF per fixture; Suffix: R. To order one RIF

per ballast; Suffix: B.

Electrical/Wiring Options: Consult factory.

Specifications:

Materials: Chassis parts are die-formed 20 gauge steel.

Reading light – Extruded aluminum lamp baffle with clear extruded acrylic shields and is removable without tools.

Ambient light – Clear acrylic lens that rotates open for easy relamping. Reflectors (Ambient and Reading Lights): Low iridescence specular pre-anodized aluminum standard.

Finish: Chassis exterior – post painted white baked polyester powder.

Electrical: Rapid start HPF, SB (Biax type) thermally protected class "P" ballast C.B.M. certified by E.T.L. If K.O. is within 3" of ballast, use wire suitable for at least 90°.

Labels: I.B.E.W. UL and ULc Listed.

This product may have a mercury containing lamp. Manage in accord with Disposal Laws. See: www.lamprecycle.org

 

Job Information

Type:

 

 

 

 

Lightolier a Genlyte company

www.lightolier.com

Technical Information: (978) 657-7600 • Fax (978) 658-0595

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710

We reserve the right to change details of design, materials and finish.

© 2007 a Genlyte company

Section 8/Folio R40-12 Rev. B
Page 4