MD*4TM 2' x 4' Recessed or Surface MD4GPSVA2SB4SB
Page 4 of 4 |
|
ORDERING INFORMATION
Explanation of Catalog Number. Example: MD4GPSVA2SB4SB120SW
MD
MD*4
Recessed or
Surface,
Patient Light
4
Fixture
Size: 2' x 4'
G
|
|
|
|
|
|
|
|
|
Ceiling |
|
|
|
|
| Louver | ||
Type: |
|
|
|
|
| Overlay/Lens: | ||
Same Unit |
|
|
|
|
| VA = Virgin Acrylic | ||
May Be Used |
|
|
|
| .095" Nominal | |||
For: Grid |
|
|
|
| Thickness | |||
|
| Louver/ | Overlay | |||||
Surface |
|
| (standard) | |||||
|
| Lens Frame: | ||||||
Mounted | AW |
|
|
| ||||
= All Components |
|
| ||||||
|
|
|
|
|
White (For single patient room)
FF= White Louver and Horizontal surfaces to blend with ceiling
PS = Traditional with Specular Louver (For multiple patient room)
2
|
|
|
|
|
|
|
|
|
|
|
|
Lamp |
|
| Lamp |
| Voltage: | Options: | |||||
Quantity: |
|
| Quantity |
| 120 or 277 | Add appropriate | |||||
(Ambient/ |
|
| 3 = 3 Lamp |
|
|
| Suffix to Catalog | ||||
Reading) |
|
| 4 = 4 Lamp |
|
|
| No. i.e. (GLR) | ||||
2 Lamps |
|
|
|
|
|
|
|
|
| ||
(Total) | Ballast Type: |
| Ballast Type: |
|
|
|
| ||||
|
|
|
|
|
|
|
| ||||
|
|
| (Ambient Reading) |
| (Examination) |
|
|
|
| ||
|
|
|
| <20THD | <10THD |
| <20THD | <10THD |
|
| |
| SB* | IB* | X3* | I3* |
|
| |||||
| (40 Watt) |
|
|
| SB* | IB* |
|
| |||
| – | PR** | – | PR** |
|
| |||||
| (40 Watt) |
|
|
| (40 Watt) | PB | – |
|
| ||
|
|
|
| LOL Dimming TT5 |
|
| |||||
| LOL Dimming TT5 | PB | – |
|
| ||||||
|
|
|
|
|
|
|
*Instant Start Standard | *Instant Start Standard | |
**Program Start | ||
**Program Start | ||
NOTE: | ||
NOTE: | ||
For TT5 UNV, you must use IB Ballast | ||
For TT5 UNV, you must use IB Ballast | ||
|
Options/Accessories
Access Plates: Top wiring access plate is shipped with fixture as standard. When access plates are required in advance for wiring convenience, specify separately. Catalog Number: ACP.
Drywall Kit or Plaster Ceiling: Order Catalog Number: FK92X4. Request Folio
Electronic Sequential Switch (Low Voltage): Switch factory mounted in fixture for ambient and reading light convenience (controlled by pillow switch, by others). Suffix: SW.
Nurses Night Light: 120 volt medium base, narrow spot, 50W reflector lamp with specular anodized mirror, field adjustable to right or left side of patient's bed (Lamp included). Suffix: NL.
Night Light: 120 volt, 3 watt, cool white LED (50,000 hours life). Suffix: LD.
Fusing: Internal
Radio Interference Filter: To order one RIF per fixture; Suffix: R. To order one RIF per
ballast; Suffix: B.
Electrical/Wiring Options: Consult factory.
Specifications:
Materials: Chassis parts are
Louver (examination light) –
Reading light – Extruded aluminum lamp baffle with clear extruded acrylic shields and is removable without tools.
Ambient light – Clear acrylic lens that rotates open for easy relamping. Reflectors (Ambient and Reading Lights): Low iridescence specular pre- anodized aluminum standard.
Finish: Cavity (Examination Light) – Powder coated flat white or black polyester enamel, 89% reflectivity. Five stage rust prevention undercoating process. Chassis exterior – post painted white baked polyester powder. Louver (examination light) PS = low iridescence specular
Specifications (continued):
Electrical: Rapid start HPF, SB (Biax type) thermally protected class "P" ballast C.B.M. certified by E.T.L. If K.O. is within 3" of ballast, use wire suitable for at least 90°.
Labels: I.B.E.W. UL and ULc Listed.
This product may have a mercury containing lamp. Manage in accord with Disposal Laws. See: www.lamprecycle.org
| Job Information | Type: |
|
|
|
| |||
Lightolier a Genlyte company | www.lightolier.com |
Technical Information: (978)
631 Airport Road, Fall River, MA 02720 • (508)
© 2007 a Genlyte company | Section 8/Folio |