Lightolier Page 3 of, NIGHT LIGHT Optional, Options, MD*COFFER MDCG2BX, Job Information, Type

Models: MDCG2BX

1 4
Download 4 pages 8.31 Kb
Page 3
Image 3
MD*COFFER MDCG2BX
SECTION 8/Folio R40-22

MD*COFFER MDCG2BX

Page 3 of 4

NIGHT LIGHT (Optional)

Indirect 9 or 7 watt PL lamp shielded by perforated mesh with internal white acrylic overlay.

No glare to any patient.

Wired for independent switching.

2'x2' RECESSED OR SURFACE, MULTI-FUNCTION PATIENT LIGHTING INDIRECT AMBIENT LIGHT WITH PERFORATED MESH SHIELD

3"

6"

12"

 

 

 

 

 

 

 

 

 

 

 

 

 

3

4

3

3

2

2

1

 

 

 

 

 

 

 

12"

Wall

3

4

3

3

2

2

1

 

 

3

4

3

3

2

2

1

 

 

 

 

Bed

 

 

 

 

 

 

 

FOOTCANDLES ON BED

 

 

 

OPTIONS

PL9 or PL7 Night Light (PL)

(Lamps not included)

Night Light

Sequential switch (SW)

Pillow speaker (by others)

MD*Coffer’s optional low voltage (1-3 volts) sequential switch mounted in the fixture is listed in compliance with UL 544 for medical and dental equipment.

SW Option (sequential switch): One red wire with black stripes and one yellow wire from the fixture can be wired to a wall receptacle (by others) for use with that manufacturers pillow speaker. The pillow speaker is used to control the television, call the nurse and control the lighting. To control the lighting it should be speci- fied to have a normally open momentary contact switch.

Pressing this switch on the pillow speaker the first time, turns the ambient light on; pressed a second time, turns the reading light on and the ambient light off; pressed a third time, turns both the ambient and reading lights on; pressed a fourth time turns both lights off. Pressing the button again repeats the cycle.

DP Option (individual switches): One red wire, one red wire with black stripes and one yellow wire from the fixture can be wired to a wall receptacle (by others) for use with manufacturers control systems (such as Hill- Rom Side Com System). To control the lighting, it should be specified to have a normally open momentary contact switch.

Pressing the first switch turns the ambient light on; pressed a second time, turns the ambient light off. Pressing the second switch the first time, turns the reading light on; pressed a second time, turns the reading light off.

TAMPER RESISTANT/GERM SHIELD

Germ Shield: Ideal for psychiatric wards and germ free environments. Fits lay-in grid

ceiling systems with 15/16" maximum ceiling tee face. The heavy duty welded extruded aluminum frame with clear 1/8" thick polycarbonate lens is fixture to ceiling system sealed with a heavy duty gasket. Request Folio R40-15 REV. A.

Job Information

 

Type:

 

 

 

 

 

 

 

Lightolier a Genlyte Thomas Company

 

www.lightolier.com

Technical Information: (978) 657-7600 • Fax (978) 658-0595

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish.

© 2002 Genlyte Thomas Group LLC (Lightolier Division) A0902

Page 3
Image 3
Lightolier Page 3 of, NIGHT LIGHT Optional, Options, MD*COFFER MDCG2BX, Job Information, Type, Sequential switch SW