Lightolier PLA2G9LP3FT Page 2 of, Photometry, Ordering Information, Options & Accessories, Type

Models: PLA2G9LP3FT

1 2
Download 2 pages 2.38 Kb
Page 2
Image 2
Page 2 of 2
Section 2/Folio G50-54 Rev. A

 

Paralyte 2424 PLA2G9LP3FT

Page 2 of 2

2' x 2' Recessed Fluorescent, 3-1/8" Deep, 9 Cell Parabolic Louver

 

Static and Air Return 3 Lamp, Twin Tube T5

Photometry

Model No. PLA2G9LP3FT120X3

ITL33751

LIGHTOLIER

PLA2G9LP3FT120X3

LER=FP-61.9 IW - 97.9 BF - 0.88

Comparative yearly lighting energy cost per 1000 lumens=$3.88

coefficients of utilization — zonal cavity method

(effective floor cavity reflectance 0.20)

 

 

 

 

RF

 

 

 

 

20

 

 

 

 

20

 

 

 

 

 

20

 

 

RC

 

 

 

 

80

 

 

 

 

50

 

 

 

 

 

30

 

 

RW

 

70

 

 

50

 

30

 

50

30

 

10

 

50

 

30

10

 

1

 

81

 

 

78

 

76

 

73

72

 

70

 

71

 

69

68

ratio

2

 

75

 

 

70

 

66

 

67

64

 

61

 

64

 

62

60

3

 

69

 

 

63

 

58

 

60

56

 

53

 

58

 

55

52

 

 

 

 

 

 

 

 

 

cavity

4

 

64

 

 

57

 

51

 

54

50

 

46

 

52

 

49

45

5

 

59

 

 

51

 

45

 

48

44

 

40

 

47

 

43

40

room

6

 

54

 

 

45

 

39

 

43

38

 

34

 

42

 

38

34

7

 

49

 

 

40

 

34

 

38

33

 

29

 

37

 

33

29

 

8

 

46

 

 

36

 

30

 

35

29

 

26

 

34

 

29

26

 

9

 

42

 

 

32

 

27

 

31

26

 

23

 

31

 

26

23

 

10

 

39

 

 

29

 

23

 

28

23

 

19

 

27

 

23

19

visual comfort probability

(rated lumens per lamp 3150.)

 

 

 

 

 

 

 

 

 

room size

 

 

 

 

 

ceiling height

 

 

 

 

 

ceiling height

 

 

W

 

 

L

 

8.5

10.0

13.0

16.0

 

 

 

8.5

10.0

13.0

 

16.0

20

 

 

20

 

 

 

57

51

51

66

 

 

 

58

51

48

 

54

20

 

 

30

 

 

 

61

55

49

50

 

 

 

61

55

48

 

48

20

 

 

40

 

 

 

64

59

53

52

 

 

 

64

58

52

 

49

20

 

 

60

 

 

 

66

61

57

55

 

 

 

66

61

56

 

52

30

 

 

20

 

 

 

63

56

52

61

 

 

 

64

56

50

 

53

30

 

 

30

 

 

 

66

59

50

47

 

 

 

66

59

49

 

47

30

 

 

40

 

 

 

68

62

54

49

 

 

 

68

61

53

 

48

30

 

 

60

 

 

 

69

64

58

52

 

 

 

70

64

56

 

51

30

 

 

80

 

 

lengthwise

71

66

60

56

 

 

crosswise

71

65

59

 

54

40

 

 

40

 

 

71

66

57

50

 

 

72

65

57

 

49

40

 

 

20

 

 

 

67

61

56

61

 

 

 

68

61

54

 

54

40

 

 

30

 

 

 

70

64

54

48

 

 

 

70

63

53

 

48

40

 

 

60

 

 

luminaries

72

68

60

53

 

 

luminaries

73

67

59

 

52

40

 

 

80

 

 

73

69

63

56

 

 

74

68

62

 

55

40

 

 

100

 

 

 

75

70

65

59

 

 

 

75

70

64

 

57

60

 

 

30

 

 

 

72

66

58

51

 

 

 

72

66

57

 

50

60

 

 

40

 

 

 

73

68

61

53

 

 

 

73

68

60

 

51

60

 

 

60

 

 

 

74

69

63

55

 

 

 

74

69

62

 

54

 

 

 

 

 

 

 

 

60

 

 

80

 

 

 

74

70

65

58

 

 

 

75

70

64

 

57

60

 

 

100

 

 

 

76

71

66

60

 

 

 

76

71

66

 

59

100

 

 

40

 

 

 

75

71

65

58

 

 

 

75

70

63

 

57

100

 

 

60

 

 

 

76

72

66

60

 

 

 

76

71

65

 

59

100

 

 

80

 

 

 

76

72

68

62

 

 

 

77

72

67

 

61

100

 

 

100

 

 

 

77

73

69

64

 

 

 

78

73

68

 

62

Ordering Information

Explanation of Catalog Number. Example: PLA2G9LP3FT120X3GLR

PL

 

A

 

 

 

 

 

Paralyte

 

Body Style:

2448:

A= Air Handling

3-1/8" Deep

 

/Static

Parabolic

Precision

Contoured

Pre-anodized

Aluminum

Louver

 

2

 

G

 

 

9

 

 

 

 

 

P

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fixture

 

Ceiling Type:

Number of

 

 

 

 

 

Ballast Cover

 

Width

G=Grid (lay-in T bar)

Cells

 

 

 

 

P=Dual V Reflector

 

 

 

 

 

 

 

 

 

L

 

Louver

 

Finish:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

= Low Iridescence

 

 

 

 

 

 

 

 

 

 

Semi-Specular (standard)

 

 

 

 

 

 

 

 

 

W = White Paint

3

Lamp

Quantity

FT

Lamp/

Fixture Length:

Twin Tube T5 (Nominal 24")

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Voltage:

 

 

 

 

 

Options:

120 or 277

 

 

 

Add appropriate

 

 

 

 

 

 

suffix to catalog

 

 

 

 

 

 

 

 

 

 

 

no., ie: (GLR)

 

 

 

 

Ballast Type:

<10THD

 

 

 

 

 

<20THD

1&2 Lamp Elec. TT5

SB*

IB*

 

(40 Watt)

X3*

I3*

1–3 Lamp Elec. TT5

 

(40 Watt)

PB*

 

LOL TT5 Dimming

 

Other dimming options. Consult factory.

*Instant Start Standard

Options & Accessories

Prewiring: 3/8” factory prewired cable (three no. 18 AWG leads, 6’ long),

Suffix: FF6, (Four no. 18 AWG leads, 6’ long), Suffix: FF14.

Fusing: Internal fast-blow fusing. Suffix: GLR. Internal slow-blow fusing. Suffix: GMF.

Fluorescent Emergency Lighting System: Factory-installed emergency power battery pack with charger and inverter, concealed in fixture channel. Operates one fluorescent lamp at reduced light output for 90 minutes.

Suffix: EM.

Radio Intererference Filter: 120 or 277 volt, 50 or 60 Hz.

One per fixture. Suffix: R. One per ballast. Suffix: B.

Electrical Options: Special wiring, fusing or dimming ballasts and installed lamps are available, consult your Lightolier representative or factory.

T-Bar Spacer: If T-bar is less than 1-1/2” deep, order Catalog Number: STC. 2 each end is required.

Specifications (continued)

Air Return: Designed to provide optimum air return. Air is returned through the lamp compartment for all ceiling systems and direct to plenum through slots in slot grid and narrow grid ceiling systems.

Materials: Chassis parts are die-formed code gauge cold rolled steel. Housing is embossed for rigidity with all edges turned up for safe handling. Louver is pre-anodized aluminum (Coilzak or equal). rails hemmed over and housing ends turned-in for safe handling.

Finish: Louver–semi-specular anodized low iridescence, vertical grain reflector sheet. Cavity–white baked polyester minimum 86% reflectance. Phosphate undercoating. Chassis exterior–black baked polyester enamel.

Electrical: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3” of ballast, use wire suitable for at least 90°.

Labels: I.B.E.W./UL and ULc Listed.

Specifications

Performance: In an installation of 3 lamp 40W Iuminaires in a room cavity ratio of 1, with reflectance of 80% ceiling, 50% wall, 20% floor, the C.U shall not be less than 78. To prevent glare the VCP shall not be less than 74 either lengthwise or crosswise (at 100fc level) and the average brightness at 65° shall not exceed 1340 foot-Iamberts. To control veiling reflections, luminaire output in the 3C°-90° zone shall not be less than 72.1%.

Job Information

 

Type:

 

 

 

Lightolier a Genlyte Thomas Company

www.lightolier.com

Technical Information: (978) 657-7600 • Fax (978) 658-0595

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish.

© 2003 Genlyte Thomas Group LLC (Lightolier Division) A0902

Page 2
Image 2
Lightolier PLA2G9LP3FT Page 2 of, Photometry, Ordering Information, Options & Accessories, Specifications continued, Type