Lightolier PTS7-1 Ordering Information, Quick Calculators, Ordering Instructions, One Light, Type

Models: PTS7-1

1 2
Download 2 pages 35.71 Kb
Page 2
Image 2
Performance & Quick Calculators

Lighting Systems PTS7-1

1BHFPG1FSJNFUFS5SPVHI3FDFTTFE%JSFDU-PVWFS-JHIU51FS'PPU4FDUJPO

Performance & Quick Calculators

CANDLEPOWER CURVE

 

ZONE

 

 

 

 

85˚

Deg

180

 

 

 

180

deg

 

 

0 deg

75˚

175

300

 

 

 

165

 

 

 

 

155

 

 

 

 

 

450

 

90

 

65˚

145

 

deg

 

135

600

 

 

 

55˚

125

 

 

 

115

 

 

 

 

750

 

 

 

 

105

 

 

 

 

95

 

 

 

 

 

900

 

 

 

45˚

90

 

 

 

 

 

85

050

 

 

 

 

75

 

 

 

 

 

65

15˚

25˚

35˚

55

45

REPORT NO: LRL 499-5D

 

 

35

LAMPS: 1-FO32T8

 

 

 

25

 

 

 

15

EFFICIENCY: 46.7%

 

 

5

 

 

0

 

 

 

 

 

CANDLEPOWER SUMMARY

 

0

45

90

135

180

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

39

15

2

2

2

153

90

5

3

3

440

120

13

8

9

560

338

79

34

14

669

532

288

64

32

754

705

512

103

55

885

833

677

225

104

969

949

778

386

285

950

920

837

704

620

833

833

833

833

833

 

 

 

 

 

COEFFICIENTS OF UTILIZATION

 

 

 

 

 

 

% EFFECTIVE CEILING CAVITY REFLECTANCE

 

 

 

 

 

80

 

 

70

 

 

 

50

 

 

 

 

 

 

% WALL REFLECTANCE

 

 

 

 

 

 

50

30

10

50

30

10

 

50

30

10

 

0

 

56

56

56

54

54

54

 

52

52

52

RATIO

1

 

50

49

47

49

48

46

 

47

46

45

3

 

41

38

35

40

37

35

 

39

36

34

CAVITY

2

 

45

43

41

44

42

40

 

43

41

39

6

 

30

27

24

30

27

24

 

29

26

24

 

4

 

37

34

31

36

33

31

 

35

33

30

 

5

 

33

30

27

33

30

27

 

32

29

27

ROOM

7

 

28

24

21

27

24

21

 

27

24

21

9

 

23

19

17

22

19

17

 

22

19

17

 

8

 

25

21

19

25

21

19

 

24

21

19

 

10

 

21

17

15

21

17

15

 

20

17

15

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ZONAL LUMEN SUMMARY

 

 

 

 

ZONE

LUMENS

% BARELAMP

% LUMINAIRE

 

0-90

 

 

1354

 

46.7

 

 

 

100.0

 

 

90-180

 

0

 

0.0

 

 

 

0.0

 

 

0-180

 

1354

 

46.7

 

 

 

100.0

 

Ordering Information

ONE LIGHT

 

 

 

 

 

Cat No.

PTS7T148

PTS7184

PTS7160

PTS7148

PTS7136

PTS7124

Size

27" to 48"

84"

60"

48"

36"

24"

Lamps

1-4 Foot

2-4 Foot

2-3 Foot

1-4 Foot

1-3 Foot

1-2 Foot

Type

Tele

Module

Module

Module

Module

Module

4 '3"-6'0"

1

 

 

 

 

1

5'3"-7'0"

1

 

 

 

1

 

6'3"-8'0"

1

 

 

1

 

 

7'3"-9'0"

1

 

1

 

 

 

8'3"-10'0"

1

 

 

1

 

1

9'3"-11'0"

1

1

 

 

 

 

10'3"-12'0"

1

 

1

 

1

 

11'3"-13'0"

1

1

 

 

 

1

12'3"-14'0"

1

1

 

 

1

 

13'3"-15'0"

1

1

 

1

 

 

14'3"-16'0"

1

1

1

 

 

 

15'3"-17'0"

1

1

 

1

 

1

16'3"-18'0"

1

2

 

 

 

 

17'3"-19'0"

1

1

1

 

1

 

18'3"-20'0"

1

2

 

 

 

1

19'3"-21'0"

1

2

 

 

1

 

20'3"-22'0"

1

2

 

1

 

 

21'3"-23'0"

1

2

1

 

 

 

22'3"-24'0"

1

2

 

1

 

1

23'3"-25'0"

1

3

 

 

 

 

24'3"-26'0"

1

2

1

 

1

 

25'3"-27'0"

1

3

 

 

 

1

26'3"-28'0"

1

3

 

 

1

 

27'3"-29'0"

1

3

 

1

 

 

28'3"-30'0"

1

3

1

 

 

 

29'3"-31'0"

1

3

 

1

 

1

30'3"-32'0"

1

4

 

 

 

 

31'3"-33'0"

1

3

1

 

1

 

32'3"-34'0"

1

4

 

 

 

1

33'3"-35'0"

1

4

 

 

1

 

34'3"-36'0"

1

4

 

1

 

 

35'3"-37'0"

1

4

1

 

 

 

36'3"-38'0"

1

4

 

1

 

1

37'3"-39'0"

1

5

 

 

 

 

38'3"-40'0"

1

4

1

 

1

 

39'3"-41'0"

1

5

 

 

 

1

40'3"-42'0"

1

5

 

 

1

 

41'3"-43'0"

1

5

 

1

 

 

42'3"-44'0"

1

5

1

 

 

 

43'3"-45'0"

1

5

 

1

 

1

44'3"-46'0"

1

6

 

 

 

 

45'3"-47'0"

1

5

1

 

1

 

46'3"-48'0"

1

6

 

 

 

1

47'3"-49'0"

1

6

 

 

1

 

48'3"-50'0"

1

6

 

1

 

 

49'3"-51'0"

1

6

1

 

 

 

50'3"-52'0"

1

6

 

1

 

1

51'3"-53'0"

1

7

 

 

 

 

52'3"-54'0"

1

6

1

 

1

 

Quick Calculators

 

 

ONE SIDE MOUNTING

 

 

 

 

 

 

 

ONE SIDE MOUNTING

 

 

NO OPPOSITE WALL

 

 

 

FT

 

 

 

6 FT BETWEEN WALLS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3.5

22

 

 

 

 

 

 

 

 

 

3.5

 

33

 

 

 

45

 

 

 

 

 

 

 

 

 

 

CEILING,

 

 

 

 

 

1.5

63

 

 

 

 

 

 

 

 

 

 

1.5

 

72

 

 

 

39

 

2.5

33

 

 

 

 

 

 

 

 

 

FROM

2.5

 

43

 

 

 

45

 

4.5

18

76

51

33

23

18

 

15

 

 

4.5

 

28

85

68

43

 

 

 

 

 

 

 

5.5

16

 

 

 

 

 

 

 

 

 

 

5.5

 

26

 

 

 

40

 

6.5

15

40

38

33

27

23

 

20

 

 

DISTANCE

6.5

 

24

49

48

37

 

9.5

12

 

 

 

9.5

 

19

28

 

7.5

14

51

45

35

28

23

 

19

 

 

 

7.5

 

22

60

55

33

 

8.5

12

 

 

 

 

 

 

 

 

 

 

8.5

 

21

 

 

 

30

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

2

4

6

8

10

 

12

 

 

 

 

 

0

2

4

6

 

 

 

DISTANCE FROM WALL, FEET

 

 

 

DISTANCE FROM WALL, FEET

 

 

 

 

 

 

 

 

TWO SIDE MOUNTING

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12 FT BETWEEN WALLS

 

 

 

 

 

 

 

 

 

 

 

1.5

76

 

 

 

 

 

 

 

76

 

 

 

 

 

 

 

 

 

 

2.5

50

 

HORIZONTAL FC

50

 

FC

 

 

 

 

 

 

 

 

3.5

41

 

 

 

 

 

 

 

41

 

 

 

 

 

 

 

 

 

 

92

73

65

73

92

 

 

VERTICAL

 

 

 

 

 

 

 

 

6.5

35

 

 

35

 

 

 

 

 

 

 

 

 

4.5

38

 

 

38

 

 

 

 

 

 

 

 

 

 

5.5

37

 

 

 

 

 

 

 

37

 

 

 

 

 

 

 

 

 

 

7.5

34

 

72

71

69

71

72

 

34

 

 

 

 

 

 

 

 

 

 

8.5

33

 

 

 

 

 

 

 

33

 

 

 

 

 

 

 

 

 

 

9.5

32

 

63

66

65

66

63

 

32

 

 

 

 

 

 

 

 

 

 

 

0

 

2

4

6

8

10

 

12

 

 

 

 

 

 

 

 

 

 

 

DISTANCE FROM WALL, FEET

 

 

 

 

 

Ordering Instructions

Individual Fixtures:

1.Order number of FIXTURES.

2.Order one END PLATE SET per fixture.

Continuous Rows:

1.Determine run length.

2.Use chart above to find catalog numbers. Each run ends with a telescoping unit.

3.Order END PLATE SET for each open run.

Square/Rectangle Patterns:

1.Consult plans and mark locations for corners.

2.Calculate net footage of each run.

3.Deduct corner dimension from each corner.

4.Determine catalog numbers the same way as a straight run.

NOTE: Add to end of catalog number for desired ballast. Blank = T12 Magnetic 120v

2 =T12 Magnetic 277v

E1 = T12 Electronic 120v

E2 = T12 Electronic 227v

E81 = T8 Electronic 120v

E82 = T8 Electronic 227v

M71 = T8 Electronic Dimming Ballast 120v

M72 = T8 Electronic Dimming Ballast 277v

Job Information

Type:

"JSQPSU3PBE'BMM3JWFS."t  t'BY  

We reserve the right to change details of design, materials and finish.