Lightolier PTS7-3 Performance, Ordering Information, Quick Calculators, Ordering Instructions

Models: PTS7-3

1 2
Download 2 pages 37.01 Kb
Page 2
Image 2
Performance

Lighting Systems PTS7-3

1BHFPG 1FSJNFUFS5SPVHI3FDFTTFE%JSFDU-PVWFSX"JS$IBOOFM-JHIU51FS'PPU4FDUJPO

Performance

CANDLEPOWER CURVE

180

 

 

 

85˚

deg

 

 

0 deg

75˚

 

 

 

300

 

 

 

 

 

 

 

450

 

90

 

65˚

 

deg

 

600

 

 

 

55˚

 

 

 

 

750

 

 

 

 

900

 

 

 

45˚

050

 

 

 

 

15˚

25˚

35˚

REPORT NO: LRL 499-5D

LAMPS: 1-FO32T8

EFFICIENCY: 46.7%

 

CANDLEPOWER SUMMARY

 

ZONE

0

45

90

135

180

Deg

 

 

 

 

 

180

0

0

0

0

0

175

0

0

0

0

0

165

0

0

0

0

0

155

0

0

0

0

0

145

0

0

0

0

0

135

0

0

0

0

0

125

0

0

0

0

0

115

0

0

0

0

0

105

0

0

0

0

0

95

0

0

0

0

0

90

0

0

0

0

0

85

39

15

2

2

2

75

153

90

5

3

3

65

440

120

13

8

9

55

560

338

79

34

14

45

669

532

288

64

32

35

754

705

512

103

55

25

885

833

677

225

104

15

969

949

778

386

285

5

950

920

837

704

620

0

833

833

833

833

833

 

 

 

 

 

COEFFICIENTS OF UTILIZATION

 

 

 

 

 

 

% EFFECTIVE CEILING CAVITY REFLECTANCE

 

 

 

 

 

80

 

 

70

 

 

 

50

 

 

 

 

 

 

% WALL REFLECTANCE

 

 

 

 

 

 

50

30

10

50

30

10

 

50

30

10

 

0

 

56

56

56

54

54

54

 

52

52

52

RATIO

1

 

50

49

47

49

48

46

 

47

46

45

3

 

41

38

35

40

37

35

 

39

36

34

 

2

 

45

43

41

44

42

40

 

43

41

39

CAVITY

4

 

37

34

31

36

33

31

 

35

33

30

6

 

30

27

24

30

27

24

 

29

26

24

ROOM

5

 

33

30

27

33

30

27

 

32

29

27

7

 

28

24

21

27

24

21

 

27

24

21

 

8

 

25

21

19

25

21

19

 

24

21

19

 

9

 

23

19

17

22

19

17

 

22

19

17

 

10

 

21

17

15

21

17

15

 

20

17

15

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ZONAL LUMEN SUMMARY

 

 

 

 

ZONE

LUMENS

% BARELAMP

% LUMINAIRE

 

0-90

 

 

1354

 

46.7

 

 

 

100.0

 

 

90-180

 

0

 

0.0

 

 

 

0.0

 

 

0-180

 

1354

 

46.7

 

 

 

100.0

 

Ordering Information

ONE LIGHT

 

 

 

 

 

Cat No.

PTS7T148A PTS7184A

PTS7160A

PTS7148A

PTS7136A

PTS7124A

Size

27" to 48"

84"

60"

48"

36"

24"

Lamps

1-4 Foot

2-4 Foot

2-3 Foot

1-4 Foot

1-3 Foot

1-2 Foot

Type

Tele

Module

Module

Module

Module

Module

4 '3"-6'0"

1

 

 

 

 

1

5'3"-7'0"

1

 

 

 

1

 

6'3"-8'0"

1

 

 

1

 

 

7'3"-9'0"

1

 

1

 

 

 

8'3"-10'0"

1

 

 

1

 

1

9'3"-11'0"

1

1

 

 

 

 

10'3"-12'0"

1

 

1

 

1

 

11'3"-13'0"

1

1

 

 

 

1

12'3"-14'0"

1

1

 

 

1

 

13'3"-15'0"

1

1

 

1

 

 

14'3"-16'0"

1

1

1

 

 

 

15'3"-17'0"

1

1

 

1

 

1

16'3"-18'0"

1

2

 

 

 

 

17'3"-19'0"

1

1

1

 

1

 

18'3"-20'0"

1

2

 

 

 

1

19'3"-21'0"

1

2

 

 

1

 

20'3"-22'0"

1

2

 

1

 

 

21'3"-23'0"

1

2

1

 

 

 

22'3"-24'0"

1

2

 

1

 

1

23'3"-25'0"

1

3

 

 

 

 

24'3"-26'0"

1

2

1

 

1

 

25'3"-27'0"

1

3

 

 

 

1

Quick Calculators

ONE SIDE MOUNTING

NO OPPOSITE WALL

1.563

2.533

3.522

4.5

18

76

51

33

23

18

15

5.516

6.515

7.5

14

51

45

35

28

23

19

8.512

9.5

12

40

38

33

27

23

20

 

 

0

2

4

6

8

10

12

 

 

 

DISTANCE FROM WALL, FEET

 

 

 

 

 

TWO SIDE MOUNTING

 

 

 

 

 

12 FT BETWEEN WALLS

 

 

1.5

 

76

 

 

 

 

 

76

 

2.5

 

50

HORIZONTAL FC

 

50

 

3.5

 

41

 

 

 

 

 

41

 

4.5

 

38

92

73

65

73

92

38

 

5.5

 

37

 

 

 

 

 

37

 

6.5

 

35

 

 

 

 

 

35

 

7.5

 

34

72

71

69

71

72

34

 

8.5

 

33

 

 

 

 

 

33

 

9.5

 

32

63

66

65

66

63

32

 

 

0

2

4

6

8

10

12

DISTANCE FROM WALL, FEET

VERTICAL FC

DISTANCE FROM CEILING, FT

STATIC PRESSURE, IN. W.G.

 

 

ONE SIDE MOUNTING

 

 

6 FT BETWEEN WALLS

 

 

 

 

 

 

1.5

72

 

 

39

 

2.5

43

 

 

45

 

3.5

33

 

 

45

 

4.5

28

85

68

43

 

5.5

26

 

 

40

 

6.5

24

 

 

37

 

7.5

22

60

55

33

 

8.5

21

 

 

30

 

9.5

19

49

48

28

 

 

0

2

4

6

 

DISTANCE FROM WALL, FEET

AIR RETURN DATA

PRESSURE VS. AIR FLOW

.10

.08

.06

.04

.03

.02

.01

2030 40 60 80 100 RETURN AIR FLOW RATE, CFM

26'3"-28'0"

1

3

 

1

27'3"-29'0"

1

3

1

 

28'3"-30'0"

1

3

1

 

29'3"-31'0"

1

3

1

1

30'3"-32'0"

1

4

 

 

31'3"-33'0"

1

3

1

1

32'3"-34'0"

1

4

 

1

33'3"-35'0"

1

4

 

1

34'3"-36'0"

1

4

1

 

35'3"-37'0"

1

4

1

 

36'3"-38'0"

1

4

1

1

37'3"-39'0"

1

5

 

 

38'3"-40'0"

1

4

1

1

39'3"-41'0"

1

5

 

1

40'3"-42'0"

1

5

 

1

41'3"-43'0"

1

5

1

 

42'3"-44'0"

1

5

1

 

43'3"-45'0"

1

5

1

1

44'3"-46'0"

1

6

 

 

45'3"-47'0"

1

5

1

1

46'3"-48'0"

1

6

 

1

47'3"-49'0"

1

6

 

1

48'3"-50'0"

1

6

1

 

49'3"-51'0"

1

6

1

 

50'3"-52'0"

1

6

1

1

51'3"-53'0"

1

7

 

 

52'3"-54'0"

1

6

1

1

Ordering Instructions

Individual Fixtures:

1.Order number of FIXTURES.

2.Order one END PLATE SET per fixture.

Continuous Rows:

1.Determine run length.

2.Use chart above to find catalog numbers. Each run ends with a telescoping unit.

3.Order END PLATE SET for each open run.

Square/Rectangle Patterns:

1.Consult plans and mark locations for corners.

2.Calculate net footage of each run.

3.Deduct corner dimension from each corner.

4.Determine catalog numbers the same way as a straight run.

NOTE: Add to end of catalog number for desired ballast. Blank = T12 Magnetic 120v

2 =T12 Magnetic 277v

E1 = T12 Electronic 120v

E2 = T12 Electronic 227v

E81 = T8 Electronic 120v

E82 = T8 Electronic 227v

M71 = T8 Electronic Dimming Ballast 120v

M72 = T8 Electronic Dimming Ballast 277v

Job Information

Type:

"JSQPSU3PBE'BMM3JWFS."t  t'BY  

We reserve the right to change details of design, materials and finish.

XXXMJHIUPMJFSDPN½1IJMJQT(SPVQt #

Page 2
Image 2
Lightolier PTS7-3 Performance, Ordering Information, Quick Calculators, Ordering Instructions, One Light, Continuous Rows