Lighting Systems
1BHFPG
Performance
CANDLEPOWER CURVE
180 |
|
|
| 85˚ |
deg |
|
|
| 75˚ |
500 |
|
|
| |
|
| 0 deg |
| |
|
|
| 65˚ | |
750 |
|
| 90 deg | |
1000 |
|
|
| 55˚ |
|
|
|
| |
1250 |
|
|
|
|
1500 |
|
|
| 45˚ |
1750 |
|
|
|
|
0˚ | 5˚ | 15˚ | 25˚ | 35˚ |
REPORT NO: LRL
LAMPS:
LUMENS: 2900
EFFICIENCY: 45.6%
Ordering Information
| CANDLEPOWER SUMMARY |
| |||
ZONE | 0 | 45 | 90 | 135 | 180 |
Deg |
|
|
|
|
|
180 | 0 | 0 | 0 | 0 | 0 |
175 | 0 | 0 | 0 | 0 | 0 |
165 | 0 | 0 | 0 | 0 | 0 |
155 | 0 | 0 | 0 | 0 | 0 |
145 | 0 | 0 | 0 | 0 | 0 |
135 | 0 | 0 | 0 | 0 | 0 |
125 | 0 | 0 | 0 | 0 | 0 |
115 | 0 | 0 | 0 | 0 | 0 |
105 | 0 | 0 | 0 | 0 | 0 |
95 | 0 | 0 | 0 | 0 | 0 |
90 | 0 | 0 | 0 | 0 | 0 |
85 | 94 | 37 | 5 | 2 | 2 |
75 | 482 | 132 | 10 | 7 | 7 |
65 | 894 | 298 | 28 | 17 | 21 |
55 | 1178 | 748 | 168 | 68 | 32 |
45 | 1387 | 1118 | 544 | 133 | 65 |
35 | 1586 | 1365 | 882 | 206 | 114 |
25 | 1679 | 1553 | 1117 | 502 | 223 |
15 | 1721 | 1617 | 1279 | 851 | 658 |
5 | 1547 | 1495 | 1369 | 1231 | 1171 |
0 | 1382 | 1382 | 1382 | 1382 | 1382 |
|
|
| COEFFICIENTS OF UTILIZATION |
|
| ||||||
|
| % EFFECTIVE CEILING CAVITY REFLECTANCE |
| ||||||||
|
|
| 80 |
|
| 70 |
|
|
| 50 |
|
|
|
|
| % WALL REFLECTANCE |
|
|
| ||||
|
| 50 | 30 | 10 | 50 | 30 | 10 |
| 50 | 30 | 10 |
| 0 | 54 | 54 | 54 | 53 | 53 | 53 |
| 51 | 51 | 51 |
RATIO | 1 | 49 | 47 | 46 | 48 | 46 | 45 |
| 46 | 45 | 44 |
3 | 39 | 36 | 34 | 39 | 36 | 34 |
| 37 | 35 | 33 | |
| 2 | 44 | 41 | 39 | 43 | 41 | 39 |
| 41 | 39 | 38 |
CAVITY | 4 | 36 | 32 | 29 | 35 | 32 | 29 |
| 34 | 31 | 29 |
6 | 29 | 25 | 23 | 29 | 25 | 22 |
| 28 | 25 | 22 | |
ROOM | 5 | 32 | 28 | 26 | 31 | 28 | 25 |
| 30 | 27 | 25 |
7 | 26 | 23 | 20 | 26 | 22 | 20 |
| 25 | 22 | 20 | |
| 8 | 24 | 20 | 18 | 23 | 20 | 17 |
| 23 | 20 | 17 |
| 9 | 21 | 18 | 15 | 21 | 18 | 15 |
| 21 | 17 | 15 |
| 10 | 20 | 16 | 14 | 19 | 16 | 14 |
| 19 | 16 | 14 |
| ZONAL LUMEN SUMMARY |
| |
ZONE | LUMENS | % BARELAMP | % LUMINAIRE |
2644 | 45.6 | 100.0 | |
0 | 0.0 | 0.0 | |
2644 | 45.6 | 100.0 |
TWO LIGHT |
|
|
|
|
| |
Cat No. | PTS7T242A PTS7T254A | PTS7296A | PTS7248A | PTS7236A | PTS7224A | |
Size | 27” to 42” | 39” to 54” | 96” | 48” | 36” | 24” |
Lamps | ||||||
Type | Tele | Tele | Module | Module | Module | Module |
1 |
|
|
|
|
| |
| 1 |
|
|
|
| |
1 |
|
|
|
| 1 | |
| 1 |
|
|
| 1 | |
| 1 |
|
| 1 |
| |
| 1 |
| 1 |
|
| |
| 1 |
|
| 1 | 1 | |
| 1 |
|
| 2 |
| |
| 1 |
| 1 | 1 |
| |
| 1 | 1 |
|
|
| |
| 1 |
| 1 | 1 | 1 | |
| 1 | 1 |
|
| 1 | |
| 1 | 1 |
| 1 |
| |
| 1 | 1 | 1 |
|
| |
| 1 | 1 |
| 1 | 1 | |
| 1 | 1 |
| 2 |
| |
| 1 | 1 | 1 | 1 |
| |
| 1 | 2 |
|
|
| |
| 1 | 1 | 1 | 1 | 1 | |
| 1 | 2 |
|
| 1 | |
| 1 | 2 |
| 1 |
| |
| 1 | 2 | 1 |
|
|
Quick Calculators
ONE SIDE MOUNTING
NO OPPOSITE WALL
1.5 112
2.557
3.538
4.5 | 30 | 138 | 100 | 65 | 46 | 36 | 30 |
5.526
6.524
7.5 | 23 | 88 | 84 | 69 | 55 | 45 | 38 |
8.522
9.5 | 21 | 68 | 70 | 62 | 53 | 45 | 39 |
|
| |
|
| 0 | 2 | 4 | 6 | 8 | 10 | 12 |
|
|
|
| DISTANCE FROM WALL, FEET | ||||||||
|
|
| TWO SIDE MOUNTING |
|
|
| ||||
|
|
| 12 FT BETWEEN WALLS |
|
| |||||
1.5 | 142 |
|
|
|
|
| 142 | |||
2.5 | 92 |
| HORIZONTAL FC | 92 | ||||||
3.5 | 77 |
|
|
|
|
| 77 |
4.572 170 144 129 144 170 72
5.5 | 69 | 69 |
6.5 | 67 | 67 |
7.565 130 135 134 135 130 65
8.5 | 63 |
|
|
|
|
| 63 |
9.5 | 60 | 115 | 124 | 125 | 124 | 115 | 60 |
0 2 4 6 8 10 12 DISTANCE FROM WALL, FEET
VERTICAL FC
DISTANCE FROM CEILING, FT
STATIC PRESSURE, IN. W.G.
ONE SIDE MOUNTING 6 FT BETWEEN WALLS
1.5 | 135 | 78 |
2.5 | 80 | 88 |
3.5 | 61 | 88 |
4.553 155 124 85
5.5 | 48 | 78 |
6.5 | 45 | 71 |
7.542 106 104 64
8.5 | 39 |
|
| 58 |
9.5 | 36 | 87 | 89 | 53 |
| 0 | 2 | 4 | 6 |
DISTANCE FROM WALL, FEET
AIR RETURN DATA
PRESSURE VS. AIR FLOW
.10
.08
.06
.04
.03
.02
.01
2030 40 60 80 100 RETURN AIR FLOW RATE, CFM
1 | 2 |
| 1 | 1 | |
1 | 2 |
| 2 |
| |
1 | 2 | 1 | 1 |
| |
1 | 3 |
|
|
| |
1 | 2 | 1 | 1 | 1 | |
1 | 3 |
|
| 1 | |
1 | 3 |
| 1 |
| |
1 | 3 | 1 |
|
| |
1 | 3 |
| 1 | 1 | |
1 | 3 |
| 2 |
| |
1 | 3 | 1 | 1 |
| |
1 | 4 |
|
|
| |
1 | 3 | 1 | 1 | 1 | |
1 | 4 |
|
| 1 | |
1 | 4 |
| 1 |
| |
1 | 4 | 1 |
|
| |
1 | 4 |
| 1 | 1 | |
1 | 4 |
| 2 |
| |
1 | 4 | 1 | 1 |
| |
1 | 5 |
|
|
| |
1 | 4 | 1 | 1 | 1 | |
1 | 5 |
|
| 1 | |
1 | 5 |
| 1 |
| |
1 | 5 | 1 |
|
| |
1 | 5 |
| 1 | 1 | |
1 | 5 |
| 2 |
| |
1 | 5 | 1 | 1 |
|
Ordering Instructions
Individual Fixtures:
1.Order number of FIXTURES.
2.Order one END PLATE SET per fixture.
Continuous Rows:
1.Determine run length.
2.Use chart above to find catalog numbers. Each run ends with a telescoping unit.
3.Order END PLATE SET for each open run.
Square/Rectangle Patterns:
1.Consult plans and mark locations for corners.
2.Calculate net footage of each run.
3.Deduct corner dimension from each corner.
4.Determine catalog numbers the same way as a straight run.
NOTE: Add to end of catalog number for desired ballast. Blank = T12 Magnetic 120v
2 =T12 Magnetic 277v
E1 = T12 Electronic 120v
E2 = T12 Electronic 227v
E81 = T8 Electronic 120v
E82 = T8 Electronic 227v
M71 = T8 Electronic Dimming Ballast 120v
M72 = T8 Electronic Dimming Ballast 277v
Job Information | Type: |
"JSQPSU3PBE'BMM3JWFS."t t'BY
We reserve the right to change details of design, materials and finish.
XXXMJHIUPMJFSDPN½1IJMJQT(SPVQt #