ALTER HIGH EFFICIENCY QHE1GPFOP232

Page 2 of 2

1’ X 4’ RECESSED DIRECT/INDIRECT FLUORESCENT 2 LAMP, T8 5'' DEEP MICROPERFORATED MESH LAMP SHIELD, STATIC

Photometry

Model No. : QHE1GPFOP232120SO

CERTIFIED TEST REPORT NO. LSCA268

COMPUTED BY LSC PROGRAM **TEST-LITE**

LIGHTOLIER-CFI 1x4 RECESSED LUMINAIRE CAT. NO. QHE1GPFOP232120SO

WHITE PAINTED REFLECTOR AND ONE PERFORATED LAMP SHIELD WITH OVERLAY TWO F32T8/TL841 32W T8 FLUORESCENT LAMPS. LUMEN RATING = 2950 LMS. ONE ADVANCE 120V 1 OR 2-LAMP ELECTRONIC BALLAST NO. REL-2P32-SC

 

 

 

 

 

 

CANDLEPOWER SUMMARY

 

OUTPUT

 

 

 

 

 

 

 

 

 

 

LUMENS

 

 

 

ANGLE ALONG

22.5

45

67.5

ACROSS

 

 

 

 

 

0

1372

1372

1372

1372

1372

 

 

 

 

 

5

1363

1376

1369

1372

1359

132

 

 

 

 

10

1362

1357

1350

1357

1362

 

 

 

 

 

15

1323

1319

1326

1343

1334

374

 

 

 

 

20

1280

1283

1287

1303

1300

 

 

 

 

 

25

1235

1234

1245

1253

1248

572

 

 

 

 

30

1161

1172

1195

1191

1193

 

 

 

 

 

35

1091

1102

1113

1111

1098

689

 

 

 

 

40

1007

1021

1023

1006

989

 

 

 

 

 

45

920

929

918

886

863

696

 

 

 

 

50

818

816

787

746

719

 

 

 

 

 

55

702

704

658

605

595

582

 

 

 

 

60

589

581

509

485

475

 

 

 

 

 

65

475

447

377

371

373

403

 

 

 

 

70

376

314

272

279

284

 

 

 

 

 

75

263

178

177

184

186

207

 

 

 

 

80

148

97

93

102

95

 

 

 

 

 

85

40

32

39

34

35

45

 

 

 

 

90

0

0

0

0

0

 

 

 

 

 

 

ZONAL LUMENS AND PERCENTAGES

 

 

 

 

 

ZONE

 

LUMENS

% LAMP

%LUMINAIRE

 

 

 

 

0-30

 

1078

 

18.28

29.15

 

 

 

 

0-40

 

1767

 

29.96

47.78

 

 

 

 

0-60

 

3045

 

51.61

82.30

 

 

 

 

0-90

 

3699

 

62.71

100.00

 

 

 

 

40-90

 

1931

 

32.75

52.22

 

 

 

 

60-90

 

654

 

11.10

17.70

 

 

 

 

90-180

0

 

.00

 

.00

 

 

 

 

0-180

 

3699

 

62.71

100.00

 

 

 

 

 

 

** EFFICIENCY = 62.7%

**

LUMINANCE SUMMARY-CD. / SQ. M.

PAINT REFLECTANCE = .91

S/MH = 1.3

 

 

 

 

 

 

 

 

 

SC = 1.3

ANGLE

ALONG

45

ACROSS

 

CERTIFIED BY:

 

 

 

45

4119

4124

3876

 

 

 

 

DATE:

 

55

3874

3644

3294

 

 

 

 

APR 27, 2004

65

3555

2833

2804

 

PREPARED FOR:

 

 

 

75

3218

2167

2288

 

 

LIGHTOLIER-CFI

 

 

85

1460

1417

1292

 

 

CORNWALL, ONTARIO

 

 

TESTED ACCORDING TO IES PROCEDURES. TEST DISTANCE EXCEEDS FIVE

TIMES THE GREATEST LUMINOUS OPENING OF LUMINAIRE.

LIGHTING SCIENCES CANADA LTD. 440 PHILLIP ST., UNIT 19 WATERLOO, ONTARIO

CERTIFIED TEST REPORT NO. LSCA268

COMPUTED BY LSC PROGRAM **TEST-LITE**

LIGHTOLIER-CFI 1x4 RECESSED LUMINAIRE CAT. NO. QVS1GPFOP232120SO

WHITE PAINTED REFLECTOR AND ONE PERFORATED LAMP SHIELD WITH OVERLAY TWO F32T8/TL841 32W T8 FLUORESCENT LAMPS. LUMEN RATING = 2950 LMS. ONE ADVANCE 120V 1 OR 2-LAMP ELECTRONIC BALLAST NO. REL-2P32-SC

COEFFICIENTS OF UTILIZATION

 

 

 

 

 

 

 

ZONAL CAVITY

METHOD

 

 

 

 

 

 

 

 

 

 

 

 

EFFECTIVE FLOOR CAVITY

REFLECTANCE = .20

 

 

 

 

 

CC

 

 

80

 

 

 

70

 

 

50

 

 

30

 

 

10

 

0

WALL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

70

50

30

10

70

50

30

10

50

30

10

50

30

10

50

30

10

0

RCR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

.75

.75 .75 .75

.73

.73 .73 .73

.70

.70 .70

.67 .67 .67

.64

.64 .64

.63

1

.69

.66 .64 .62

.67

.65 .63 .61

.62

.61 .59

.60 .59 .57

.58

.57 .55

.54

2

.63

.59 .55 .52

.62

.58 .54 .51

.55

.52 .50

.53 .51 .49

.52

.50 .48

.46

3

.58

.52 .48 .44

.57

.51 .47 .44

.50

.46 .43

.48 .45 .42

.46

.44 .41

.40

4

.54

.47 .42 .38

.52

.46 .41 .37

.44

.40 .37

.43 .39 .36

.42

.39 .36

.35

5

.49

.41 .36 .32

.48

.41 .36 .32

.39

.35 .32

.38 .34 .31

.37

.34 .31

.30

6

.45

.37 .32 .28

.44

.37 .31 .28

.35

.31 .28

.34 .30 .27

.33

.30 .27

.26

7

.42

.33 .28 .25

.41

.33 .28 .24

.32

.27 .24

.31 .27 .24

.30

.27 .24

.22

8

.38

.30 .25 .21

.37

.29 .25 .21

.29

.24 .21

.28 .24 .21

.27

.23 .21

.19

9

.35

.27 .22 .18

.34

.27 .22 .18

.26

.21 .18

.25 .21 .18

.25

.21 .18

.17

10

.33

.25 .19 .16

.32

.24 .19 .16

.24

.19 .16

.23 .19 .16

.22

.19 .16

.15

 

 

 

DETERMINED IN ACCORDANCE WITH CURRENT IES PUBLISHED PROCEDURES

 

 

 

 

 

 

 

 

LUMINAIRE INPUT WATTS =

56.5

 

 

 

 

 

 

 

 

LABORATORY RESULT MAY NOT BE REPRESENTATIVE OF FIELD PERFORMANCE.

 

 

 

 

 

 

BALLAST FACTORS HAVE NOT BEEN APPLIED.

 

 

 

 

Ordering Information Explanation of Catalogue Number Example: QHE2GPFOP232120SO

 

QHE

 

1

 

G

 

 

PF

 

 

OP

 

 

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

QUALITY

 

 

CEILING TYPE

 

 

 

 

 

 

 

 

 

LAMP

 

HIGH

 

 

Standard exposed

 

 

 

 

 

 

QUANTITY

EFFICIENCY

 

 

T-grid ceilings

 

 

 

 

 

 

 

 

 

 

 

Recessed direct

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

indirect soft

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

light high

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

efficiency

FIXTURE

 

 

 

 

LAMP SHIELD

 

 

 

 

 

 

 

optical system

WIDTH

 

 

 

 

PF = Microperforated

 

 

 

 

 

 

 

 

1'

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LAMP SHIELD

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DETAIL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OP = One piece

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(no center slot)

 

 

 

32

LAMP/FIXTURE

LENGTH

(NOMINAL 48'') 32 = 32W T8

120

 

SO

 

 

 

 

 

 

 

 

 

 

 

 

VOLTAGE

 

 

 

 

OPTIONS

120V

 

 

 

R = Radio

277V

 

 

 

Interference Filter

347V

 

 

 

O = Emergency Lighting

 

 

 

 

 

System (for Canada)

 

 

 

 

 

N = Emergency Lighting

 

 

 

 

 

System (for U.S.)

 

 

 

 

 

 

 

 

 

 

 

 

BALLAST

 

 

OC = Magnetic T8

 

 

SO = Electronic linear T8 instant start

 

 

SR = Electronic linear T8 rapid start

 

 

PS = PowerSpec

SPECIFICATIONS

MATERIALS: One piece chassis constructed from die formed 20 gauge cold rolled steele. Reflectors - 95% reflectance baked white acrylic matte paint finish. Soft white acrylic film on inside of lamp shield conceals lamp image. FINISH: Chassis exterior - phosphate undercoating, baked white acrylic matte paint finish.

ELECTRICAL: Rapid start HPF, thermally protected class “P” ballast (Bi-tube type). If K.Os are within 3” of ballast use wire suitable for at least 90C. LABELS: Listed by CSA, UL

Job Information Type:

Lightolier a Genlyte Thomas Company

Technical Information: (978) 657-7600 - (978) 658-0595

631 Airport Road, Fall River, MA 02720 - (508) 679-8131 C.F.I. Division of Canlyte, Inc.

525 Education Road, Cornwall, Ontario, Canada K6H 6C7 - (613) 938-6221 We reserve the right to change details of design, materials and finish. © 2004 Genlyte Thomas Group LLC (Lightolier Division)