Sidelyte Recessed Fluorescent SIS2GPF2FT
Page 2 of 2
Model No. SIS2GPF2FT120SBLER = FP - 42.4 IW - 72 BF - 0.88 Comparative yearly lighting energy cost per
1000 lumens = $5.66
Report Number: G2004263
Catalog Number: SIS2GPF2FT120SB
Lamps: FT40 40W BIAX
Luminaire: SIS 2'x2' with 2 perforated side baskets.
Ballast:
Report is based on 3150 Lumens per lamp. Efficiency: 55.1%
CIE |
|
|
|
| |||||
Plane: |
|
|
|
|
| ||||
Spacing Criteria: |
|
| 1.3 |
|
| 1.4 | |||
Shielding Angles: |
|
| 90 |
|
| 90 | |||
Plane: |
|
|
|
|
| ||||
Luminous Length: |
| 22.966 |
| 23.843 | |||||
COEFFICIENTS OF UTILIZATION – |
|
| |||||||
ZONAL CAVITY METHOD. EFFECTIVE |
| ||||||||
FLOOR CAVITY REFLECTANCE 0.200 |
| ||||||||
RC |
| 80 |
|
| 50 |
|
| 30 |
|
RW | 70 | 50 | 30 | 50 | 30 | 10 | 50 | 30 | 10 |
01 | 64 | 61 | 58 | 57 | 55 | 53 | 55 | 53 | 51 |
02 | 58 | 53 | 48 | 49 | 46 | 43 | 47 | 44 | 42 |
03 | 52 | 46 | 41 | 43 | 39 | 35 | 41 | 38 | 35 |
04 | 48 | 40 | 35 | 38 | 33 | 30 | 37 | 33 | 29 |
05 | 44 | 36 | 30 | 34 | 29 | 26 | 33 | 29 | 25 |
06 | 40 | 32 | 27 | 31 | 26 | 22 | 29 | 25 | 22 |
07 | 38 | 29 | 24 | 28 | 23 | 20 | 27 | 23 | 20 |
08 | 35 | 27 | 21 | 25 | 21 | 18 | 25 | 20 | 17 |
09 | 33 | 24 | 19 | 23 | 19 | 16 | 23 | 19 | 16 |
10 | 31 | 22 | 18 | 22 | 17 | 14 | 21 | 17 | 14 |
LUMINANCE DATA IN CANDELA/SQ. METER
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. | |||
45 | 1267. | 1430. | 1587. |
55 | 1120. | 1464. | 1753. |
65 | 914. | 1650. | 2161. |
75 | 785. | 2110. | 2717. |
85 | 562. | 727. | 810. |
Direct/indirect 2' x 2' with Perforated Baskets
Static, 2 Lamp TT5
CANDELA DISTRIBUTION
| 0.0 | 45.0 | 90.0 | FLUX |
0 | 1060 | 1060 | 1060 |
|
5 | 1056 | 1052 | 1054 |
|
15 | 1002 | 1008 | 1019 | 285 |
25 | 906 | 928 | 953 | 428 |
35 | 779 | 822 | 869 | 515 |
45 | 622 | 702 | 779 | 541 |
55 | 446 | 583 | 698 | 517 |
65 | 268 | 484 | 634 | 465 |
75 | 141 | 379 | 488 | 358 |
85 | 34 | 44 | 49 | 69 |
90 | 0 | 0 | 0 |
|
|
|
|
|
|
ZONAL LUMEN SUMMARY
ZONE | LUMENS | % LAMP | % FIXT |
0813 | 14.8 | 24.8 | |
1328 | 24.1 | 40.5 | |
2387 | 43.4 | 72.8 | |
3279 | 59.6 | 100.0 | |
0000 | 0.0 | 000.0 | |
3279 | 59.6 | 100.0 |
Ordering Information
Explanation of Catalog Number. Example: SIS2GPF2FT120SB
SI
S
2
G
P
F
2
FT
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Sidelyte: | Body Style: | Fixture | Ceiling Type | Perforated | Single | Lamp | Lamp | Voltage: |
|
| Options: | ||||
Direct/Indirect | S= Static | Width |
|
| Lamp Shield | White | Quantity: | (By Others) | 120, 277 or |
| Add appropriate | ||||
Recessed with |
|
|
|
|
|
| Reflector | 2=2 Lamp | FT=Twin Tube T5 |
|
| suffix to catalog | |||
|
|
|
|
|
|
| |||||||||
Perforated Mesh |
|
|
|
|
|
|
|
|
|
|
|
|
| no., ie: (GLR) | |
|
|
|
|
|
|
|
|
|
|
|
|
| |||
Shield |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Ballast | Type: |
|
| |
|
|
|
|
|
|
|
|
|
|
| <20THD <10THD | ||||
|
|
|
|
|
|
|
|
|
|
| SB * | IB * | |||
|
|
|
|
|
|
|
|
|
|
| (40 Watt) |
|
|
| |
|
|
|
|
|
|
|
|
|
|
| – | PR * | |||
|
|
|
|
|
|
|
|
|
|
| (40 Watt) Program Start |
|
|
| |
|
|
|
|
|
|
|
|
|
|
| BE * | BP * | |||
|
|
|
|
|
|
|
|
|
|
| (50 Watt) Program Start |
|
|
| |
|
|
|
|
|
|
|
|
|
|
| – | BF * | |||
|
|
|
|
|
|
|
|
|
|
| (55 Watt) Program Start |
|
|
|
Options/Accessories
Fusing: Internal
Internal
Drywall Kit: Order Catalog Number: FK92X2.
Specifications
Performance: In an installation of 2 lamp 40W luminaires in a room cavity ratio of 1, with reflectance 80% ceiling, 50% walls, 20% floor, the C.U. shall not be less than .61. To reduce glare the average brightness at 65° shall not exceed 2161 candelas per square meter. To control veiling reflections, luminaire output in the
Materials: Chassis parts are
Lamp Shields: 22 gauge steel perforated mesh lamp shield with white acrylic overlay.
Finish: Chassis
Lamp Shield: Baked flat white acrylic enamel.
LOL Dimming TT5 | PB * | – * |
(40 Watt) |
|
|
* Instant Start Standard |
|
|
NOTE:
For TT5 UNV voltage you must use PR, BP or BF
Ballast Code.
Specifications (continued)
Electrical: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°.
Labels: I.B.E.W. UL and ULc Listed.
Job Information | Type: |
|
|
Lightolier a Genlyte company | www.lightolier.com |
Technical Information: (978) | |
631 Airport Road, Fall River, MA 02720 • (508) | |
We reserve the right to change details of design, materials and finish. | |
© 2006 a Genlyte company | Section 5/Folio |